Powered by BEINEI 50HZ 220-440V 17-124KVA | ||||||||||||
Model | LTP | PRP | Engine | Fuel Cons. | Cylinder | Displacement | Gov. | Dimention | Weight | |||
KVA / KW | KVA/KW | Model | Origin | L/H(100%) | L | L*W*H (MM) | KGS | |||||
MC17AD | 17 | 13 | 15 | 12 | F2L912 | CN | 3.96 | 2L/NA | 1.880 | M | 1460*900*1170 | 588 |
MC28AD | 28 | 22 | 25 | 20 | F3L912 | CN | 6.62 | 3L/NA | 2.828 | M | 1460*900*1170 | 680 |
MC33AD | 33 | 26 | 30 | 24 | F4L912 | CN | 8.68 | 4L/NA | 3.770 | M | 1650*900*1170 | 764 |
MC39AD | 39 | 31 | 35 | 28 | F4L913 | CN | 9.22 | 4L/NA | 4.086 | M | 1850*820*1200 | 890 |
MC44AD | 44 | 35 | 40 | 32 | F4L912T | CN | 11.13 | 4L/TC | 3.770 | M | 1850*820*1200 | 970 |
MC55AD | 55 | 44 | 50 | 40 | F6L912 | CN | 13.02 | 4L/NA | 5.655 | M | 2250*820*1240 | 1080 |
MC61AD | 61 | 48 | 55 | 44 | F6L913 | CN | 13.84 | 4L/NA | 6.128 | M | 2250*820*1240 | 1120 |
MC69AD | 69 | 55 | 63 | 50 | F6L912T | CN | 16.55 | 4L/TC | 5.655 | M | 2250*820*1240 | 1200 |
MC83AD | 83 | 66 | 75 | 60 | BF4L913 | CN | 15.70 | 4L/TC | 4.086 | E | 2250*820*1240 | 1320 |
MC99AD | 99 | 79 | 90 | 72 | BF6L913 | CN | 23.88 | 4L/TCA | 6.128 | E | 2250*820*1240 | 1320 |
MC124AD | 124 | 99 | 113 | 90 | BF6L913C | CN | 29.85 | 4L/TCA | 6.128 | E | 2250*820*1240 | 1480 |
Powered by DEUTZ 50HZ 220-440 V 22-825KVA | ||||||||||||
Model | LTP | PRP | Engine | Fuel Cons. | Cylinder | Displacement | Gov. | Dimention | Weight | |||
KVA / KW | KVA/KW | Model | Origin | L/H(100%) | L | L*W*H (MM) | (KGS) | |||||
MC22D | 22 | 18 | 20 | 16 | BFM3 G1 | CN | 5.40 | 4L/NA | 3.168 | E | 1600*880*1250 | 560 |
MC33D | 33 | 26 | 30 | 24 | BFM3 G2 | CN | 7.70 | 4L/NA | 3.168 | E | 1600*880*1250 | 582 |
MC44D | 44 | 35 | 40 | 32 | BFM3T | CN | 10.30 | 4L/TC | 3.168 | E | 1600*880*1250 | 640 |
MC55D | 55 | 44 | 50 | 40 | BFM3C | CN | 11.20 | 4L/TCA | 3.168 | E | 1600*880*1250 | 680 |
MC66D | 66 | 53 | 60 | 48 | BF4M2012 | CN | 13.70 | 4L/TC | 4.040 | M | 1870*980*1500 | 970 |
MC83D | 83 | 66 | 75 | 60 | BF4M2012C G1 | CN | 18.10 | 4L/TCA | 4.040 | M | 1960*980*1500 | 1010 |
MC99D | 99 | 79 | 90 | 72 | BF4M2012C G2 | CN | 21.30 | 4L/TCA | 4.040 | E | 1960*980*1500 | 1040 |
MC110D | 110 | 88 | 100 | 80 | BF4M1013EC G1 | CN | 20.90 | 4L/TCA | 4.764 | M | 2140*980*1700 | 1180 |
MC124D | 124 | 99 | 113 | 90 | BF4M1013EC G2 | CN | 24.20 | 4L/TCA | 4.764 | E | 2140*980*1700 | 1220 |
MC138D | 138 | 110 | 125 | 100 | BF4M1013FC | CN | 28.90 | 4L/TCA | 4.764 | E | 2140*980*1700 | 1310 |
MC176D | 176 | 141 | 160 | 128 | BF6M1013EC G1 | CN | 35.90 | 6L/TCA | 7.146 | M | 2280*980*1700 | 1480 |
MC198D | 198 | 158 | 180 | 144 | BF6M1013EC G2 | CN | 39.20 | 6L/TCA | 7.146 | E | 2280*980*1700 | 1590 |
MC206D | 206 | 165 | 188 | 150 | BF6M1013FC G2 | CN | 40.60 | 6L/TCA | 7.146 | E | 2640*1150*1790 | 1710 |
MC220D | 220 | 176 | 200 | 160 | BF6M1013FC G3 | CN | 45.60 | 6L/TCA | 7.146 | E | 2640*1150*1790 | 1760 |
MC275D | 275 | 220 | 250 | 200 | TCD 8.0 | CN | 51.60 | 6L/TCA | 7.800 | ECU | 2710*1150*1790 | 2640 |
MC330D | 330 | 264 | 300 | 240 | TCD 8.7 | CN | 51.57 | 6L/TCA | 8.700 | ECU | 3050*1150*1760 | 2820 |
MC1000D | 1000 | 800 | 325 | 260 | TCD12.1 G1 | CN | 64.64 | 6L/TCA | 12.100 | ECU | 3050*1150*1760 | 2820 |
MC413D | 413 | 330 | 375 | 300 | TCD12.1 G2 | CN | 76.79 | 6L/TCA | 12.100 | ECU | 3050*1150*1760 | 2990 |
MC495D | 495 | 396 | 450 | 360 | TCD13.0 G1 | CN | 88.77 | 6L/TCA | 12.940 | ECU | 3600*1400*2100 | 3170 |
MC550D | 550 | 440 | 500 | 400 | TCD13.0 G2 | CN | 100.06 | 6L/TCA | 12.940 | ECU | 3600*1400*2100 | 3270 |
MC248D | 248 | 198 | 225 | 180 | BF6M1015-LA GA | CN | 49.60 | 6V/TC | 11.906 | E | 2650*1520*2100 | 2320 |
MC275D | 275 | 220 | 250 | 200 | BF6M1015C-LA G1A | CN | 53.80 | 6V/TCA | 11.906 | E | 2650*1520*2100 | 2320 |
MC303D | 303 | 242 | 275 | 220 | BF6M1015C-LA G2A | CN | 60.40 | 6V/TCA | 11.906 | E | 2750*1520*2100 | 2510 |
MC344D | 344 | 275 | 313 | 250 | BF6M1015C-LA G3A | CN | 67.20 | 6V/TCA | 11.906 | E | 2850*1520*2100 | 2520 |
MC385D | 385 | 308 | 350 | 280 | BF6M1015C-LA G4 | CN | 74.00 | 6V/TCA | 11.906 | E | 2850*1520*2100 | 2610 |
MC413D | 413 | 330 | 375 | 300 | BF6M1015CP-LA G | CN | 79.30 | 6V/TCA | 11.906 | E | 2950*1520*2100 | 2695 |
MC481D | 481 | 385 | 438 | 350 | BF8M1015C-LA G1A | CN | 92.50 | 8V/TCA | 15.875 | E | 3100*1850*2240 | 3120 |
MC495D | 495 | 396 | 450 | 360 | BF8M1015C-LA G2 | CN | 97.50 | 8V/TCA | 15.875 | E | 3100*1850*2240 | 3240 |
MC523D | 523 | 418 | 475 | 380 | BF8M1015CP-LA G1A | CN | 100.00 | 8V/TCA | 15.875 | E | 3100*1850*2240 | 3300 |
MC550D | 550 | 440 | 500 | 400 | BF8M1015CP-LA G2 | CN | 108.40 | 8V/TCA | 15.875 | E | 3100*1850*2240 | 3380 |
MC605D | 605 | 484 | 550 | 440 | BF8M1015CP-LA G4 | CN | 116.10 | 8V/TCA | 15.875 | E | 3100*1850*2240 | 3450 |
MC619D | 619 | 495 | 563 | 450 | BF8M1015CP-LA G5 | CN | 123.10 | 8V/TCA | 15.875 | E | 3100*1850*2240 | 4200 |
MC756D | 756 | 605 | 688 | 550 | HC12V132ZL-LAG1A | CN | 137.40 | 12V/TCA | 23.812 | E | 3700*1600*2200 | 4200 |
MC825D | 825 | 660 | 750 | 600 | HC12V132ZL-LAG2A | CN | 152.60 | 12V/TCA | 23.812 | E | 3700*1600*2200 | 4200 |
General Feature | ||||||||||||||||||
♦ Assembled by diesel engine and Brushless alternator. | ||||||||||||||||||
Three filters as standard, fuel and water separator as optional. | ||||||||||||||||||
♦ Radiator and fan with safety guard. | ||||||||||||||||||
♦ Single bearing alternator IP 23, Insulation Class H. | ||||||||||||||||||
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank. | ||||||||||||||||||
♦ Automatic control panel and 3 poles circuit breaker, internal cable. | ||||||||||||||||||
♦ 12V or 24V battery, battery wires. | ||||||||||||||||||
♦ Battery and float battery charger as standard supply scope. | ||||||||||||||||||
♦ Fuel level indicator in meter and panel | ||||||||||||||||||
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers. |
1.Q: What is your MOQ of this item?
A:1 SetCustomerized Fuel Tank
1.Volume: 500L, 1000L,1500L,2000L,3000L etc.
2.Plate steel construction
3.Fuel level meter
4.Fuel transfer systems
5.Double wall
6.Electric fuel pump
7.Fuel level sensor (indicated on control module)
8.Fuel automatic filling system
9.Tank in genset base, top, built-in, seperately stand etc
Icon | Indicator Light | Reason | Fault Analysis |
Low oil pressure alarm |
Low oil pressure alarm |
When oil pressure does not reduce normally, the light is on. |
-General because of a lack of oil or lubrication system failure caused by (refueling or replacing the oil filter) -When occurs this fault should automatically shutdown generator sets immediately. |
High water temperature alarm |
High water temperature alarm |
When the water temperature has risen to a level higher than or equal to the sensor setting, the light is on. |
-General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Low fuel level alarm |
Low fuel level alarm |
When a fuel level has been detected by the sensor fitted to the daily tank, the light is on. |
-General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Battery charger fault alarm |
Battery charger fault alarm |
If the charging system has fault, when engine running, the light is off. |
-Battery charging system fault caused. -The light is on at the initial start, when the charger reaches a certain speed, the light is off. -This failure will not lead to automatic shutdown generating units. |
Crank failure alarm |
Crank failure alarm |
When the generator set failed three times (or six times) in a row starting, the light is on. |
-Oil supply system or re-start the system failure caused. |
Overload or breaker tripping alarm |
Overload or breaker tripping alarm |
When overloading or Short circuit, the light is on. Tripping circuit breakers cause generator set load out. |
-In this fault, it need to load or unload some parts to eliminate short-circuit, and then re-close the circuit breaker. |