Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator

Product Details
Customization: Available
After-sales Service: Responsible
Warranty: 12 Months or 1000 Operation Hours
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (21)
  • Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator
  • Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator
  • Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator
  • Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator
  • Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator
  • Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Genset Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MC
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Water/Air Cooled Deutz or Beinei
Alternator Brand
Mecca Power, Leroy Somer, Optional
Control Panel
Deepsea/Comap/Deif/Smartgen and Others
Canopy Type
Silent Soundproof/Weather Proof/Anti-Rusted Proof
Frequency(Hz)
50Hz/60Hz
Voltage Output
220-440V; 110-480V
Application
Telecom Communication Base
Double Stacking
Remote Control Generator
Governing Type
Mech/Elec/ECU/Ecm/Adec/Hpcr
Soundless Generator
Diesel Generator Continuous Running 24/7
ATS
as Application Requested
Certificate Available
CE, ISO, OEM Authorization etc.
Diesel Powered Generator
China Brand Generator
Super Silent Generator
Emergency Diesel Generator
Automatic Fuel Feeding
Big Fuel Tank Generator
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
850211
Production Capacity
1000/Year

Packaging & Delivery

Package Size
160.00cm * 88.00cm * 125.00cm
Package Gross Weight
640.000kg

Product Description

Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.


Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator
Product Description

In the dynamic realm of telecommunications, every connection matters. MECCA Diesel Generators provide a seamless power supply, ensuring your telecom operations run smoothly 24/7.

(1)1000pcs 20-75kVA/Year
(2)Water/Air Cooled Engine
(3)Remote Control
(4)Continuous Running
(5)Double Stacking
(6)With Big Fuel Tank(1000L,1500L,2000L,3000L etc.)
(7)Automatic Fuel Feeding
Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator
Specification
Powered by BEINEI                                                                                          50HZ   220-440V 17-124KVA 
Model LTP PRP Engine Fuel Cons. Cylinder Displacement Gov. Dimention Weight
KVA / KW  KVA/KW  Model Origin L/H(100%) L L*W*H (MM) KGS
MC17AD 17  13  15  12 F2L912 CN 3.96  2L/NA 1.880  M 1460*900*1170 588 
MC28AD 28  22  25  20 F3L912  CN 6.62  3L/NA 2.828   M  1460*900*1170 680 
MC33AD 33  26  30  24 F4L912  CN 8.68  4L/NA 3.770  M 1650*900*1170 764 
MC39AD 39  31  35  28 F4L913  CN 9.22  4L/NA 4.086   M  1850*820*1200 890 
MC44AD 44  35  40  32 F4L912T  CN 11.13  4L/TC 3.770  M 1850*820*1200 970 
MC55AD 55  44  50  40 F6L912  CN 13.02  4L/NA 5.655   M  2250*820*1240 1080 
MC61AD 61  48  55  44 F6L913  CN 13.84  4L/NA 6.128  M 2250*820*1240 1120 
MC69AD 69  55  63  50 F6L912T  CN 16.55  4L/TC  5.655   M  2250*820*1240 1200 
MC83AD 83  66  75  60 BF4L913 CN 15.70  4L/TC  4.086  E 2250*820*1240 1320 
MC99AD 99  79  90  72 BF6L913  CN 23.88  4L/TCA 6.128  E 2250*820*1240 1320 
MC124AD 124  99  113  90 BF6L913C CN 29.85  4L/TCA 6.128  E 2250*820*1240 1480 
Powered by  DEUTZ                                                                              50HZ   220-440 V   22-825KVA                                                          
Model LTP PRP Engine Fuel Cons. Cylinder Displacement Gov. Dimention   Weight
KVA / KW  KVA/KW  Model Origin L/H(100%) L L*W*H (MM) (KGS)
MC22D 22  18  20  16 BFM3 G1 CN 5.40  4L/NA 3.168  E 1600*880*1250 560 
MC33D 33  26  30  24 BFM3 G2 CN 7.70  4L/NA 3.168  E 1600*880*1250 582 
MC44D 44  35  40  32 BFM3T CN 10.30  4L/TC 3.168  E 1600*880*1250 640 
MC55D 55  44  50  40 BFM3C CN 11.20  4L/TCA 3.168  E 1600*880*1250 680 
MC66D 66  53  60  48 BF4M2012 CN 13.70  4L/TC 4.040   M  1870*980*1500 970 
MC83D 83  66  75  60 BF4M2012C G1 CN 18.10  4L/TCA 4.040   M  1960*980*1500 1010 
MC99D 99  79  90  72 BF4M2012C G2 CN 21.30  4L/TCA 4.040  E 1960*980*1500 1040 
MC110D 110  88  100  80 BF4M1013EC G1 CN 20.90  4L/TCA 4.764   M  2140*980*1700 1180 
MC124D 124  99  113  90 BF4M1013EC G2 CN 24.20  4L/TCA 4.764  E 2140*980*1700 1220 
MC138D 138  110  125  100 BF4M1013FC CN 28.90  4L/TCA 4.764  E 2140*980*1700 1310 
MC176D 176  141  160  128 BF6M1013EC G1 CN 35.90  6L/TCA 7.146  M 2280*980*1700 1480 
MC198D 198  158  180  144 BF6M1013EC G2 CN 39.20  6L/TCA 7.146  E 2280*980*1700 1590 
MC206D 206  165  188  150 BF6M1013FC G2 CN 40.60  6L/TCA 7.146  E 2640*1150*1790 1710 
MC220D 220  176  200  160 BF6M1013FC G3 CN 45.60  6L/TCA 7.146  E 2640*1150*1790 1760 
MC275D 275  220  250  200 TCD 8.0 CN 51.60  6L/TCA 7.800  ECU 2710*1150*1790 2640 
MC330D 330  264  300  240 TCD 8.7 CN 51.57  6L/TCA 8.700  ECU 3050*1150*1760 2820 
MC1000D 1000  800  325  260 TCD12.1 G1 CN 64.64 6L/TCA 12.100  ECU 3050*1150*1760 2820 
MC413D 413  330  375  300 TCD12.1 G2 CN 76.79 6L/TCA 12.100  ECU 3050*1150*1760 2990 
MC495D 495  396  450  360 TCD13.0 G1 CN 88.77  6L/TCA 12.940  ECU 3600*1400*2100 3170 
MC550D 550  440  500  400 TCD13.0 G2 CN 100.06  6L/TCA 12.940  ECU 3600*1400*2100 3270 
MC248D 248  198  225  180 BF6M1015-LA GA CN 49.60  6V/TC 11.906  E 2650*1520*2100 2320 
MC275D 275  220  250  200 BF6M1015C-LA G1A CN 53.80  6V/TCA 11.906  E 2650*1520*2100 2320 
MC303D 303  242  275  220 BF6M1015C-LA G2A CN 60.40  6V/TCA 11.906  E 2750*1520*2100 2510 
MC344D 344  275  313  250 BF6M1015C-LA G3A CN 67.20  6V/TCA 11.906  E 2850*1520*2100 2520 
MC385D 385  308  350  280 BF6M1015C-LA G4 CN 74.00  6V/TCA 11.906  E 2850*1520*2100 2610 
MC413D 413  330  375  300 BF6M1015CP-LA G CN 79.30  6V/TCA 11.906  E 2950*1520*2100 2695 
MC481D 481  385  438  350 BF8M1015C-LA G1A CN 92.50  8V/TCA 15.875  E 3100*1850*2240 3120 
MC495D 495  396  450  360 BF8M1015C-LA G2 CN 97.50  8V/TCA 15.875  E 3100*1850*2240 3240 
MC523D 523  418  475  380 BF8M1015CP-LA G1A CN 100.00  8V/TCA 15.875  E 3100*1850*2240 3300 
MC550D 550  440  500  400 BF8M1015CP-LA G2 CN 108.40  8V/TCA 15.875  E 3100*1850*2240 3380 
MC605D 605  484  550  440 BF8M1015CP-LA G4 CN 116.10  8V/TCA 15.875  E 3100*1850*2240 3450 
MC619D 619  495  563  450 BF8M1015CP-LA G5 CN 123.10  8V/TCA 15.875  E 3100*1850*2240 4200 
MC756D 756  605  688  550 HC12V132ZL-LAG1A CN 137.40  12V/TCA 23.812  E 3700*1600*2200 4200 
MC825D 825  660  750  600 HC12V132ZL-LAG2A CN 152.60  12V/TCA 23.812  E 3700*1600*2200 4200 
General Feature
♦ Assembled by diesel engine and Brushless alternator. 
 Three filters as standard, fuel and water separator as optional.
♦ Radiator and fan with safety guard.
♦ Single bearing alternator IP 23, Insulation Class H.
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank.
♦ Automatic control panel and 3 poles circuit breaker, internal cable.
♦ 12V or 24V battery, battery wires.
♦ Battery and float battery charger as standard supply scope.
♦ Fuel level indicator in meter and panel
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers. 
Genset Workshop

Telecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel GeneratorTelecom Silent Generators Double Stacking 25kVA 35kVA 50kVA 60kVA 75kVA 100kVA Remote Control Air Cooled Deutz Beinei Continuous Electric Start Diesel Generator

FAQ

1.Q: What is your MOQ of this item?

A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.

 

Customerized Fuel Tank

1.Volume: 500L, 1000L,1500L,2000L,3000L etc.

2.Plate steel construction

3.Fuel level meter

4.Fuel transfer systems

5.Double wall

6.Electric fuel pump 

7.Fuel level sensor (indicated on control module)

8.Fuel automatic filling system

9.Tank in genset base, top, built-in, seperately stand etc


CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling. 
All items from following are seperately packed without connection.
 
SKD:Semi Knock Down Generator
Partially assembled generator. 
Part of the following items you choose will be assembled.
 

-----------------------------------------------------------------------------------------------MAINTENANCE---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier