50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator

Product Details
Customization: Available
After-sales Service: Responsible
Warranty: 12 Months or 1200 Operation Hours
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (21)
  • 50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
  • 50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
  • 50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
  • 50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
  • 50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
  • 50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Specification
  • Genset Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MC
Type
Basic Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Ordinary
Excitation Mode
Static Exciter
Engine Brand
Chinese Engine Sdec
Alternator Brand
Leroy Somer, Stamford, Mecca
Control Panel
Deepsea/Comap/Deif/Smartgen
Diesel Engine Generator
Electrical Electric Start Generator Set
Canopy Type
Silent Soundproof/Weather Proof/Anti-Rusted Proof
Frequency(Hz)
50Hz/60Hz, 1500rpm 1800rpm
Voltage Output
230/400V, 220-480V
Application
Standby/Industrial/Construction/Power Plant
Accessory[a]
Spare Parts Documents
500 kVA Generator
Diesel Generator for Sale
Governing Type
Mech/Elec/ECU/Ecm/Adec/Hpcr
ATS
Auto Start Generator
Certificate Available
CE, ISO, OEM Authorization etc.
Silent Diesel Generator
Silent Diesel Generators for Sale
Diesel Group 100kVA
Dg Generator
Transport Package
Both Standard Marine Packing and Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
85021
Production Capacity
1000/Year

Packaging & Delivery

Package Size
341.00cm * 137.00cm * 215.00cm
Package Gross Weight
4590.000kg

Product Description

Company Profile

Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled.

As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, Deutz, MTU, Doosan, Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc. Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in buildings, constructions, Telecom, data centers, mining, power plant,etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America.

With over 10 years of experience in manufacturing and exporting energy products, the Mecca team will provide you full-service solutions. BELIVE THAT WE ARE WORTHY OF YOUR TRUST!

50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
Product Description
The SDEC 400KW/500KVA Silent Type Diesel Generator is a high-performance, reliable power solution designed to meet the most demanding energy requirements in a variety of applications. Engineered for efficiency, durability, and quiet operation, this generator is the ideal choice for industries, construction sites, commercial establishments, and backup power needs.
  • Silent Operation: Equipped with a robust noise-reducing enclosure, the generator operates at low noise levels, making it suitable for environments where noise reduction is essential.
  • Engine Technology: Powered by a high-quality SDEC diesel engine, known for its durability, fuel efficiency, and long service life. The engine is designed to handle both continuous and emergency power needs.
  • Fuel Efficiency: With advanced fuel injection and engine design, the SDEC diesel generator ensures reduced fuel consumption, helping to lower operating costs while maintaining optimal performance.
  • Compact & Robust Design: The compact structure allows for easy installation and space-saving without compromising on durability and reliability. The generator is built to withstand harsh operating conditions.
  • Automatic Control Panel: Features a user-friendly control panel with an automatic start/stop system, remote monitoring capabilities, and various safety protection functions, such as overload, low oil pressure, and high temperature alarms.
50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel GeneratorView More Products Click Here......
Specification
Powered by SDEC                                                                                    50HZ  220-440 V  17-1100KVA 
Model LTP PRP Engine Cylinder Gov.
KVA / KW  KVA/KW  Model Origin
MC17SD 17  13  15  12 4Z2.3-G11 CN 4L M
MC22SD 22  18  20  16 4Z2.7-G11 CN 4L M
MC28SD 28  22  25  20 4Z3.0-G11 CN 4L M
MC34SC 34  28  31  25 4Z3.2-G11 CN 4L M
MC41SD 41  33  38  30 4ZT3.2-G11 CN 4L M
MC17SD 17  13  15  12 4Z2.3-G21 CN 4L E
MC22SD 22  18  20  16 4Z2.7-G21 CN 4L E
MC28SD 28  22  25  20 4Z3.0-G21 CN 4L E
MC34SD 34  28  31  25 4Z3.2-G21 CN 4L E
MC44SD 44  35  40  32 4ZT3.2-G21 CN 4L E
MC55SD 55  44  50  40 4ZT3.5-G21 CN 4L E
MC69SD 69  55  63  50 4ZT4.1-G21 CN 4L E
MC76SD 76  61  69  55 4ZTAA4.1-G21 CN 4L E
MC83SD 83  66  75  60 4ZTAA4.1-G22 CN 4L E
MC55SD 55  44  50  40 4HT4.3-G21 CN 4L E
MC69SD 69  55  63  50 4HT4.3-G22 CN 4L E
MC88SD 88  70  80  64 4HT4.3-G23 CN 4L E
MC110SD 110  88  100  80 4HTAA4.3-G21 CN 4L E
MC127SD 127  101  115  92 4HTAA4.3-G23 CN 4L E
MC138SD 138  110  125  100 4HTAA4.3-G22 CN 4L E
MC151SD 151  121  138  110 6HTAA6.5-G21 CN 6L E
MC165SD 165  132  150  120 6HTAA6.5-G22 CN 6L E
MC206SD 206  165  188  150 6HTAA6.5-G23 CN 6L E
MC220SD 220  176  200  160 6DTAA8.9-G21 CN 6L E
MC248SD 248  198  225  180 6DTAA8.9-G24 CN 6L E
MC275SD 275  220  250  200 6DTAA8.9-G23 CN 6L E
MC344SD 344  275  313  250 6ETAA11.8-G22 CN 6L E
MC385SD 385  308  350  280 6ETAA11.8-G21 CN 6L E
MC413SD 413  330  375  300 6ETAA12.8-G22 CN 6L E
MC440SD 440  352  400  320 6ETAA12.8-G21 CN 6L E
MC495SD 495  396  450  360 6ETAA12.8-G31 CN 6L ECU
MC550SD 550  440  500  400 6ETAA12.8-G310 CN 6L ECU
MC550SD 550  440  500  400 6KTAA25-G311 CN 6L ECU
MC633SD 633  506  575  460 6KTAA25-G310 CN 6L ECU
MC688SD 688  550  625  500 6KTAA25-G39 CN 6L ECU
MC770SD 770  616  700  560 6KTAA25-G38 CN 6L ECU
MC825SD 825  660  750  600 6KTAA25-G32 CN 6L ECU
MC908SD 908  726  825  660 6KTAA25-G31 CN 6L ECU
MC990SD 990  792  900  720 6KTAA25-G320 CN 6L ECU
MC1100SD 1100  880  1000  800 6KTAA25-G321 CN 6L ECU
Powered by SDEC                                                                                60HZ   110-480 V 22-1100KVA 
Model LTP PRP Engine Cylinder Gov.
KVA / KW  KVA/KW  Model Origin
MC22SD 22  18  20  16  4Z2.3-G12 CN 4L M
MC28SD 28  22  25  20  4Z2.7-G12 CN 4L M
MC33SD 33  26  30  24  4Z3.0-G12 CN 4L M
MC41SD 41  33  38  30  4Z3.2-G12 CN 4L M
MC47SD 47  37  43  34  4ZT3.2-G12 CN 4L M
MC22SD 22  18  20  16  4Z2.3-G21 CN 4L E
MC28SD 28  22  25  20  4Z2.7-G21 CN 4L E
MC33SD 33  26  30  24  4Z3.0-G21 CN 4L E
MC41SD 41  33  38  30  4Z3.2-G21 CN 4L E
MC47SD 47  37  43  34  4ZT3.2-G21 CN 4L E
MC66SD 66  53  60  48  4ZT3.5-G21 CN 4L E
MC83SD 83  66  75  60  4ZT4.1-G21 CN 4L E
MC88SD 88  70  80  64  4ZTAA4.1-G21 CN 4L E
MC89SD 89  72  81  65  4ZTAA4.1-G22 CN 4L E
MC69SD 69  55  63  50  4HT4.3-G21 CN 4L E
MC74SD 74  59  68  54  4HT4.3-G22 CN 4L E
MC94SD 94  75  85  68  4HT4.3-G23 CN 4L E
MC121SD 121  97  110  88  4HTAA4.3-G21 CN 4L E
MC138SD 138  110  125  100  4HTAA4.3-G23 CN 4L E
MC138SD 138  110  125  100  4HTAA4.3-G22 CN 4L E
MC165SD 165  132  150  120  6HTAA6.5-G21 CN 6L E
MC176SD 176  141  160  128  6HTAA6.5-G22 CN 6L E
MC220SD 220  176  200  160  6HTAA6.5-G23 CN 6L E
MC250SD 250  200  228  182  6DTAA8.9-G21 CN 6L E
MC275SD 275  220  250  200  6DTAA8.9-G24 CN 6L E
MC303SD 303  242  275  220  6DTAA8.9-G23 CN 6L E
MC385SD 385  308  350  280  6ETAA11.8-G22 CN 6L E
MC385SD 385  308  350  280  6ETAA11.8-G21 CN 6L E
MC440SD 440  352  400  320  6ETAA12.8-G22 CN 6L E
MC440SD 440  352  400  320 6ETAA12.8-G21 CN 6L E
MC495SD 495  396  450  360 6ETAA12.8-G32 CN 6L ECU
MC495SD 495  396  450  360 6ETAA12.8-G31.1 CN 6L ECU
MC550SD 550  440  500  400 6ETAA12.8-G310.1 CN 6L ECU
MC619SD 619  495  563  450 6KTAA25-G311 CN 6L ECU
MC688SD 688  550  625  500 6KTAA25-G310 CN 6L ECU
MC770SD 770  616  700  560 6KTAA25-G39 CN 6L ECU
MC770SD 770  616  700  560 6KTAA25-G38 CN 6L ECU
MC825SD 825  660  750  600 6KTAA25-G32.1 CN 6L ECU
MC908SD 908  726  825  660 6KTAA25-G31.1 CN 6L ECU
MC990SD 990  792  900  720 6KTAA25-G320.1 CN 6L ECU
MC1100SD 1100  880  1000  800 6KTAA25-G321.1 CN 6L ECU
Alternator Data
♦ Operate either 50Hz or 60Hz. ♦Stator grease insulation covered
♦ Standard enclosure IP23, but IP44, IP55 for option ♦Rotator and excitation high polymer
♦ Insulation class H.  ♦ Resist the corruption oil and acid
♦ Shunt excitataion systems. ♦Rotator balance is in accordance with BS5625  
♦ AREP or PMG system for options.  standard 12.5
♦ Automatic voltage regulator ♦High-quality lubrication sealed long-time bearing
♦ Single bearing alternator ♦Rotator silicon steel close tight
Standard Accessories
*Auto Control Panel *Starting Motor
*Main Ciruit Breaker *Exhaust silencer
*Fuel tank *Starting battery
*Base Frame *Float battery charger
*Filter  *Flange
MORE DETAILED SPEC. CONTACT US...
Genset Workshop

50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator50Hz/60Hz 400kw 500kVA Silent Type Chinese Sdec Diesel Generator
FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service? A: Yes 7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.



-----------------------------------------------------------------------------------------------Maintenance---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.


Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier