• 3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
  • 3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
  • 3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
  • 3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
  • 3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
  • 3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant

3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant

After-sales Service: Responsible
Warranty: 12 Months or 1000 Operation Hours
Type: Self-Starting Diesel Generator
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant pictures & photos
3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
US $50,000-200,000 / SET
Min. Order: 1 SET
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Fujian, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (20)
  • Overview
  • Product Description
  • Specification
  • Genset Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MC
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Mtu/Cummins/Mitsubishi/Sme Series All Range
Control Panel
UK Deepsea/Comap/Smartgen/Deif
Cylinders
6-20 Cylinders
High Voltage
3.3kv/4.16kv/6kv/6.3kv/6.6kv/10kv/10.5kv/11kv/13.8
Frequency(Hz)
50Hz/60Hz, 1500prm/1800rpm
Application
Building/Power Plant/Construction/Data Center
Silent Diesel Generator
Brushless Alternator
Diesel Generator Set
Electric Start Power Generator
Perkins Generator Set
Emergency Diesel Generator
Diesel Powered Generator
Container Generator for Outdoor Use
Industrial Generators
Diesel Electric Generator
Power Generator Set
Backup Diesel Generator Set
10MW Generator Set
Cop Diesel Generator Set
Certificate Available
CE, ISO, OEM Authorization etc.
Governing Type
Mech/Elec/ECU/Ecm/Adec/Hpcr
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
850211
Production Capacity
1000/Year

Packaging & Delivery

Package Size
4495.00cm * 2122.00cm * 2295.00cm
Package Gross Weight
7150.000kg

Product Description

Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.

With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. 

3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
Product Description

MECCA POWER 3.3KV-13.8KV high voltage gensets advantages of high output voltage and low output current make low power loss, long transmission distance and low comprehensive cost.
The simple system with less paralleled devices is easy to operate.Less fault points and low comprehensive cost.

This genset is designed with advanced fuel injection technology, making it more efficient than conventional genset. Domestic advanced technology and high-quality raw materials also provide a guarantee for the durability of high voltage generator. MECCA high voltage generators are high practicability, strong reliability, allowing long-term stable operation, safe and efficient,which are ideal for applications where power and efficiency are a top priority, such as large industrial settings and data centers.

3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant
View more products click here...
Specification
Powered by  MTU                                                                                                                                                     50HZ  220-440 V   500-3600KVA 
Model LTP PRP Engine Fuel Cons. Cyl. Disp. Gov. Dimention Weight
KVA / KW  KVA/KW  Model Origin L/H(100%) L L*W*H (MM) KGS
MC880M 880 704  800 640  12V2000G65 CN 184.0 12V 23.9 ADEC 4100*1810*2130 6100
MC1000M 1000 800  900 720  16V2000G25 CN 210.0 16V 31.8 ADEC 4495*2122*2295 7000
MC1100M 1100 880  1000 800  16V2000G65 CN 230.8 16V 31.8 ADEC 4495*2122*2295 7150
MC1250M 1250 1000  1125 900  18V2000G65 CN 264.5 16V 31.8 ADEC 4840*1825*2165 8000
MC1375M 1375 1100  1250 1000  18V2000G26F CN 261.1 18V 35.8 ADEC 4840*1825*2165 8100
MC1815M 1815 1452  1650 1320 12V4000G23F CN 338.1 12V 57.2 ADEC 6350*2150*2500 12500
MC2021M 2021 1617  1837.5 1470 12V4000G63F CN 373.1 12V 57.2 ADEC 6350*2150*2500 13000
MC2300M 2300 1840  2087.5 1670 16V4000G23F CN 428.1 16V 76.3 ADEC 7085*2250*2500 14500
MC2475M 2475 1980  2250 1800 16V4000G63F CN 465.5 16V 76.3 ADEC 7085*2250*2500 15000
MC2750M 2750 2200  2500 2000 20V4000G23F CN 521.2 20V 95.4 ADEC 7160*2555*2930 20500
MC3080M 3080 2464  2800 2240 20V4000G63F CN 567.5 20V 95.4 ADEC 7160*2555*2930 21000
MC3300M 3300 2640  3000 2400 20V4000G63LF CN 610.5 20V 95.4 ADEC 7160*2555*2930 21000
MC500M 500 400  450 360  10V1600G10F DE 101.3 10V 17.5 ADEC 3225*1485*2070 3850
MC550M 550 440  500 400  10V1600G20F DE 110.9 10V 17.5 ADEC 3225*1485*2070 3870
MC660M 660 528  600 480  12V1600G10F DE 131.7 12V 21 ADEC 3387*1531*2140 4890
MC700M 700 560  644 515  12V2000G25 DE 140.0 12V 23.9 ADEC 4100*1810*2130 6100
MC725M 725 580  660 528  12V1600G20F DE 144.9 12V 21 ADEC 3387*1531*2140 3784
MC1512M 1512 1210  1375 1100 12V4000G14RF DE 307.6 12V 57.2 ADEC 6150*2150*2500 12000
MC1815M 1815 1452  1650 1320 12V4000G14F DE 351.5 12V 57.2 ADEC 6350*2150*2500 12500
MC2020M 2020 1616  1837.5 1470 12V4000G24F DE 398.2 12V 57.2 ADEC 6350*2150*2500 13000
MC2300M 2300 1840  2087.5 1670 16V4000G14F DE 452.1 16V 76.3 ADEC 7085*2250*2500 14500
MC2500M 2500 2000  2250 1800 16V4000G24F DE 491.6 16V 76.3 ADEC 7085*2250*2500 15000
MC2750M 2750 2200  2500 2000 20V4000G14F DE 561.8 20V 95.4 ADEC 7160*2555*2930 20500
MC3080M 3080 2464  2800 2240 20V4000G24F DE 611.6 20V 95.4 ADEC 7160*2555*2930 21000
MC3300M 3300 2640  3000 2400 20V4000G34F DE 651.2 20V 95.4 ADEC 7160*2555*2930 21000
MC3600M 3600 2880  3250 2600 20V4000G44F DE 653.0 20V 95.4 ADEC 7160*2555*2930 21000
Powered by  Mitsubishi                                                                                                         50HZ  220-440 V    500-3600KVA 
Model LTP PRP Engine Fuel Cons. Cyl. Disp. Gov. Dimention Weight
KVA / KW  KVA/KW  Model Origin L/H(100%) L*W*H (MM) KGS
MC688MS 688  550  625 500  S6R2-PTA-C CN 139 6L 30.0  E 3770*1400*2000 6140 
MC825MS 825 660  750 600  S6R2-PTAA-C CN 170 6L 30.0  E 4100*1400*2150 6410 
MC1375MS 1375 1100  1250 1000  S12R-PTA-C CN 266 12V 49.0  E 4880*2000*2380 10560 
MC1540MS 1540 1232  1400 1120  S12R-PTA2-C CN 281 12V 49.0  E 4980*2000*2380 10660 
MC1650MS 1650 1320  1500 1200  S12R-PTAA2-C CN 308 12V 49.0  E 4980*2200*2380 10860 
MC1915MS 1915 1532  1750 1400  S16R-PTA-C CN 310 16V 65.4  E 5490*2190*2495 11410 
MC2100MS 2100 1680  1875 1500  S16R-PTA2-C CN 418 16V 65.4  E 5640*2170*2495 11710 
MC2250MS 2250 1800  2050 1640  S16R-PTAA2-C CN 432 16V 65.4  E 5820*2210*2670 13500 
MC2500MS 2500 2000  2250 1800  S16R2-PTAW-C CN 476 16V 79.9 E 6790*2200*2525 16400 
MC825MT 825 660  750 600  S6R2-PTAA JP 170 6L 30.0  E 4100*1400*2150 6410 
MC880MT 880 704  800 640  S12A2-PTA JP 174 12V 33.9 E 4350*1900*2310 6410 
MC1100MT 1100 880  1000 800  S12H-PTA JP 220 12V 37.1 E 4880*2000*2380 9860
MC1400MT 1400 1120  1250 1000  S12R-PTA JP 266 12V 49.0  E 4880*2000*2380 10560 
MC1540MT 1540 1232  1400 1120  S12R-PTA2 JP 281 12V 49.0 E 4980*2000*2380 10660
MC1650MT 1650 1320  1500 1200  S12R-PTAA2 JP 308 12V 49.0 E 4980*2200*2380 10860
MC1915MT 1915 1532  1750 1400  S16R-PTA JP 310 16V 65.4 E 5490*2190*2495 11410
MC2100MT 2100 1680  1875 1500  S16R-PTA2 JP 418 16V 65.4 E 5640*2170*2495 11710
MC2250MT 2250 1800  2050 1640  S16R-PTAA2 JP 432 16V 65.4 E 5820*2210*2670 13500
MC2500MT 2500 2000  2250 1800  S16R2-PTAW JP 476 16V 79.9 E 6790*2200*2525 16400
MC2750MT 2750 2200  2500 2000  S16R2-PTAW-E JP 528 16V 79.9 E 7230*3064*3762 20000
MORE DETAILED INFO CONTACT US...
Alternator Specifications
Alternator Model STAMFORD TAL/PI/UCI/HCI/LVI Series
Output power 600kW-1640kW
Voltage control AVR
Number of phase 3
Power factor (Cos Phi) 0.8
Insulation Class H
Number of Wires  6
Protection 23
Altitude  ≤ 1000 m
Number of Pole  4
Exciter type AREP
Voltage regulation ±0.5%           
Totale Harmonic distortion at no load < 4 % - on load < 4 %
Bearing   Single
Coupling Direct
Alternator Data
♦ Operate either 50Hz or 60Hz. ♦Stator grease insulation covered
♦ Standard enclosure IP23, but IP44, IP55 for option ♦Rotator and excitation high polymer
♦ Insulation class H.  ♦ Resist the corruption oil and acid
♦ Shunt excitataion systems. ♦Rotator balance is in accordance with BS5625  
♦ AREP or PMG system for options.  standard 12.5
♦ Automatic voltage regulator ♦High-quality lubrication sealed long-time bearing
♦ Single bearing alternator ♦Rotator silicon steel close tight
Standard Accessories
*Auto Control Panel *Starting Motor
*Main Ciruit Breaker *Exhaust silencer
*Fuel tank *Starting battery
*Base Frame *Float battery charger
*Filter  *Flange
Genset Workshop

3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant3.3kv-13.8kv High Voltage Diesel Generator Genset 10MW 12MW 20MW 30MW Cummins/Mtu/Mitsubishi Engine Generators for Power Plant

FAQ

Payment Terms:

By telegraphic transfer: 30% deposit on signing of sales contract; and balance 70% before dispatch. 
                                
Delivery:
Approximately 4-8 weeks upon order confirmation.

Service Guarantee:
Before Service: According to the clients' requirement and actual situation, we will furnish the technology consultation and kinds of information.  

After Service: Guarantee for one year or 1200 running hours (accord to whichever reach first) from installed date.
During the guarantee period, we will provide the free easy-damaged spare-parts for problems caused by our quality of production or raw material, except the damageable spare parts of diesel engine caused by customer's incorrect man-made operation. After checking, our company provides cost spare-parts maintenance for gensets .  


Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.

CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling. 
All items from following are seperately packed without connection.
 
SKD:Semi Knock Down Generator
Partially assembled generator. 
Part of the following items you choose will be assembled.
 
Advantage:
Prompt delivery
Reduced tax to win more competition
Lower transportation fees to save cost
Localized production to win more tenders. 
Increased production to offer more job opportunity for the government




-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now