China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator

Product Details
Customization: Available
After-sales Service: Responsible
Warranty: 12 Months or 1000 Operation Hours
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (21)
  • China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator
  • China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator
  • China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator
  • China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator
  • China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator
  • China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Genset Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MC
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Cummins/Perkins/Mtu/Mitsubishi/Sme/Yuchai
Control Panel
Deepsea/Comap/Smartgen/Deif, etc.
Cylinders
6-20 Cylinders
High Voltage
3.3kv/6kv/6.3kv/6.6kv/10kv/10.5kv/11kv/13.8kv
Frequency(Hz)
50Hz/60Hz
Application
Building/Commercial/Construction/Data Center
Accessory
Spare Parts Document
Diesel Generator Set
Electric Start Power Generator
Governing Type
Mech/Elec/ECU/Ecm/Adec/Hpcr
Dg Set
Emergency Diesel Generator
Diesel Powered Generator
China Generator for Sale
Certificate Available
CE, ISO, OEM Authorization etc.
Industrial Generators
Diesel Electric Generator
Power Generating Set
Power Plant Generator
Emergency Generator
Standby Power Generator
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
85021
Production Capacity
1000/Year

Packaging & Delivery

Package Size
716.00cm * 255.00cm * 293.00cm
Package Gross Weight
20500.000kg

Product Description

Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled.

As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, Deutz, MTU, Doosan, Mitsubishi,FPT,VOLVO,Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc.

Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in buildings, constructions, Telecom, data centers, Mining, Power Plant,Oil Gas,etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America.

China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator
Product Description
China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator
China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator

China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power GeneratorChina Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power GeneratorChina Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power GeneratorChina Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power GeneratorChina Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power GeneratorChina Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator

Specification
Powered by  MTU                                                                                                                                                   50HZ  220-440 V 500-3600KVA 
Model LTP PRP Engine Fuel Cons. Cyl. Disp. Gov.
KVA / KW  KVA/KW  Model Origin L/H(100%) L
MC880M 880 704  800 640  12V2000G65 CN 184.0 12V 23.9 ADEC
MC1000M 1000 800  900 720  16V2000G25 CN 210.0 16V 31.8 ADEC
MC1100M 1100 880  1000 800  16V2000G65 CN 230.8 16V 31.8 ADEC
MC1250M 1250 1000  1125 900  18V2000G65 CN 264.5 16V 31.8 ADEC
MC1375M 1375 1100  1250 1000  18V2000G26F CN 261.1 18V 35.8 ADEC
MC1815M 1815 1452  1650 1320 12V4000G23F CN 338.1 12V 57.2 ADEC
MC2021M 2021 1617  1837.5 1470 12V4000G63F CN 373.1 12V 57.2 ADEC
MC2300M 2300 1840  2087.5 1670 16V4000G23F CN 428.1 16V 76.3 ADEC
MC2475M 2475 1980  2250 1800 16V4000G63F CN 465.5 16V 76.3 ADEC
MC2750M 2750 2200  2500 2000 20V4000G23F CN 521.2 20V 95.4 ADEC
MC3080M 3080 2464  2800 2240 20V4000G63F CN 567.5 20V 95.4 ADEC
MC3300M 3300 2640  3000 2400 20V4000G63LF CN 610.5 20V 95.4 ADEC
MC500M 500 400  450 360  10V1600G10F DE 101.3 10V 17.5 ADEC
MC550M 550 440  500 400  10V1600G20F DE 110.9 10V 17.5 ADEC
MC660M 660 528  600 480  12V1600G10F DE 131.7 12V 21 ADEC
MC700M 700 560  644 515  12V2000G25 DE 140.0 12V 23.9 ADEC
MC725M 725 580  660 528  12V1600G20F DE 144.9 12V 21 ADEC
MC1512M 1512 1210  1375 1100 12V4000G14RF DE 307.6 12V 57.2 ADEC
MC1815M 1815 1452  1650 1320 12V4000G14F DE 351.5 12V 57.2 ADEC
MC2020M 2020 1616  1837.5 1470 12V4000G24F DE 398.2 12V 57.2 ADEC
MC2300M 2300 1840  2087.5 1670 16V4000G14F DE 452.1 16V 76.3 ADEC
MC2500M 2500 2000  2250 1800 16V4000G24F DE 491.6 16V 76.3 ADEC
MC2750M 2750 2200  2500 2000 20V4000G14F DE 561.8 20V 95.4 ADEC
MC3080M 3080 2464  2800 2240 20V4000G24F DE 611.6 20V 95.4 ADEC
MC3300M 3300 2640  3000 2400 20V4000G34F DE 651.2 20V 95.4 ADEC
MC3600M 3600 2880  3250 2600 20V4000G44F DE 653.0 20V 95.4 ADEC
Alternator Specifications
Alternator Model STAMFORD TAL/PI/UCI/HCI/LVI Series
Output power 500kW-3600kW
Voltage control AVR
Number of phase 3
Power factor (Cos Phi) 0.8
Insulation Class H
Number of Wires  6
Protection 23
Altitude  ≤ 1000 m
Number of Pole  4
Exciter type AREP
Voltage regulation ±0.5%           
Totale Harmonic distortion at no load < 4 % - on load < 4 %
Bearing   Single
Coupling Direct
Alternator Data
♦ Operate either 50Hz or 60Hz. ♦Stator grease insulation covered
♦ Standard enclosure IP23, but IP44, IP55 for option ♦Rotator and excitation high polymer
♦ Insulation class H.  ♦ Resist the corruption oil and acid
♦ Shunt excitataion systems. ♦Rotator balance is in accordance with BS5625  
♦ AREP or PMG system for options.  standard 12.5
♦ Automatic voltage regulator ♦High-quality lubrication sealed long-time bearing
♦ Single bearing alternator ♦Rotator silicon steel close tight
Standard Accessories
*Auto Control Panel *Starting Motor
*Main Ciruit Breaker *Exhaust silencer
*Fuel tank *Starting battery
*Base Frame *Float battery charger
*Filter  *Flange
CONTACT US FOR MORE SPEC.
Genset Workshop

China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power GeneratorChina Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power GeneratorChina Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator
China Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power GeneratorChina Factory Price Diesel Genset 2000kw 2200kw 2500kVA 2750kVA 3000kVA Medium High Voltage Cummins/Mtu/Mitsubishi/Sme/Yuchai Standby Power Generator

FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.



-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier