Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup

Product Details
Customization: Available
After-sales Service: Responsible
Warranty: 12 Months or 1200 Operation Hours
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (21)
  • Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup
  • Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup
  • Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup
  • Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup
  • Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup
  • Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup
Find Similar Products
  • Overview
  • Generator Introduction
  • Specification
  • Genset Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MC
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Chinese Yuchai
Alternator
Stamford / Leroy Somer /Mecc Alte
Control Panel
UK Deepsea, Smartgen, Optional
Super Silent Generator Price
Three Phase Generator Price
Canopy Type
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
Frequency(Hz)
50Hz/60Hz, 1500rpm 1800rpm
Voltage Output
110-480V, 3.3kv-13.8kv Medium High Voltage
Application[a]
Mining/Construction/Data Center/Oil Gas
Application[B]
Commercial/Power Plant/Factory/Industrial
Accessory
Spare Parts Documents
Governing Type
Mech/Elec/ECU/Ecm/Adec/Hpcr
Electric Start Generator
Industrial Power Generator Set
Certificate Available
CE, ISO, OEM Authorization etc.
AC Three Phase Diesel Generators
Power Genset Unit
Emergency Generator
Electrical Diesel Generating Set
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
85021
Production Capacity
1000/Year

Packaging & Delivery

Package Size
666.00cm * 226.00cm * 280.00cm
Package Gross Weight
14000.000kg

Product Description

Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled.

As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, Deutz, MTU, Doosan, FPT,Mitsubishi,Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc. Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in buildings, constructions, Telecom, data centers, mining,power plant, etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America.


Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup
Generator Introduction

MECCA-2500KVA 40HQ Containerized Yuchai Generator

This cutting-edge generator is ready to deliver unmatched performance and reliability for all your energy needs. Perfect for large-scale operations, this unit ensures continuous power with efficiency and durability.
Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction BackupIndustrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction BackupIndustrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction BackupIndustrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction BackupIndustrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup

Specification
Powered by YUCHAI                                                                                                   50HZ   220-440V   31-4510KVA 
Model LTP PRP Engine  GOV.
KVA / KW  KVA/KW  Model Origin
MC31YC 31  25  29  23 YCV2.5N35-G20 CN E
MC41YC 41  33  38  30 YCV2.5T45-G20 CN E
MC52YC 53  42  48  38 YCV2.5T55-G20 CN E
MC55YC 55  44  50  40 YCD4.2N60-G20 CN E
MC83YC 83  66  75  60 YCD4.2T90-G20 CN E
MC96YC 96  77  88  70 YCA4.8T100-G20 CN E
MC106YC 106  85  96  77 YCA4.8T110-G20 CN E
MC138YC 138  110  125  100 YCA4.8TAA140-G20 CN E
MC165YC 165  132  150  120 YCA4.8TAA180-G20 CN E
MC165YC 165  132  150  120 YCB6.9TAA180-G20 CN E
MC190YC 190  152  173  138 YCB6.9TAA205-G20 CN E
MC226YC 226  181  206  165 YCA7.3TAA245-G20 CN E
MC261YC 261  209  238  190 YCQ7.5260-G30 CN E
MC261YC 261  209  238  190 YCMK10TAA285-G20 CN E
MC323YC 323  259  294  235 YCMK10TAA350-G20 CN E
MC386YC 386  309  351  281 YCMK10TAA420-G20 CN E
MC459YC 459  367  418  334 YCMJ12TAA500-G20 CN E
MC503YC 503  402  456  365 YCMJ12540-G30 CN ECU
MC551YC 551  441  501  401 YCT16TAA600-G20 CN E
MC606YC 606  485  551  441 YCT16TAA660-G20 CN E
MC606YC 606  485  551  441 YCT16660-G31 CN ECU
MC715YC 715  572  650  520 YCTD20780-G31 CN ECU
MC770YC 770  616  701  561 YCTD20840-G31 CN ECU
MC831YC 831  665  756  605 YCTD20900-G31 CN ECU
MC919YC 919  735  835  668 YCTD201000-G30 CN ECU
MC984YC 984  787  894  715 YCTH281070-G31 CN ECU
MC1121YC 1121  897  1019  815 YCTH281220-G31 CN ECU
MC1210YC 1210  968  1100  880 YCTH281320-G31 CN ECU
MC1210YC 1210  968  1100  880 YCC401320-G31 CN ECU
MC1398YC 1398  1118 1270  1016 YCC401520-G31 CN ECU
MC1375YC 1375  1100 1250  1000 YCTD40TA1500-G30 CN ECU
MC1538YC 1538  1230 1400  1120 YCTD40TA1680-G30 CN ECU
MC1678YC 1678  1342 1525  1220 YCTD40TA1830-G30 CN ECU
MC1850YC 1850  1480 1681  1345 YCTD40TA2000-G30 CN ECU
MC2090YC 2090  1672 1900  1520 YCTD52TA2270-G30 CN ECU
MC2313YC 2313  1850 2100  1680 YCTD52TA2510-G30 CN ECU
MC2481YC 2481  1985 2256  1805 YCTD52TA2700-G30 CN ECU
MC2481YC 2481  1985 2256  1805 YCC80TA2700-G31 CN ECU
MC2758YC 2758  2206 2506  2005 YCC80TA3000-G30 CN ECU
MC2758YC 2758  2206 2506  2005 YCC105TA3000-G31 CN ECU
MC3033YC 3033  2426 2756  2205 YCC105TA3300-G31 CN ECU
MC3308YC 3308  2646 3006  2405 YCC105TA3600-G31 CN ECU
MC3675YC 3675  2940 3341  2673 YCC105TA4000-G31 CN ECU
MC3859YC 3859  3087 3508  2806 YCC105TA4200-G30 CN ECU
MC4139YC 4139  3311 3763  3010 YCC105TA4500-G30 CN ECU
MC4510YC 4510  3608 4100  3280 YCC105TA4900-G30 CN ECU
Powered by YUCHAI                                                                                            60HZ  110-480V  31-2481KVA 
Model LTP PRP Engine GOV.
KVA / KW  KVA/KW  Model Origin
MC31YC 31  25  29  23 YCV2.5N35-G21 CN E
MC41YC 41  33  38  30 YCV2.5T45-G21 CN E
MC53YC 53  42  48  38 YCV2.5T55-G21 CN E
MC60YC 60  48  55  44 YCD4.2N65-G21 CN E
MC76YC 76  61  69  55 YCD4.2T80-G21 CN E
MC91YC 91  73  83  66 YCD4.2T100-G21 CN E
MC121YC 121  97  110  88 YCB6.9T130-G21 CN E
MC148YC 148  118  134  107 YCB6.9T160-G21 CN E
MC193YC 193  154  175  140 YCB6.9TAA210-G21 CN E
MC226YC 226  181  206  165 YCA7.3TAA245-G21 CN E
MC262YC 262  210  238  190 YCMK10TAA285-G21 CN E
MC330YC 330  264  300  240 YCMK10TAA360-G21 CN E
MC386YC 386  309  351  281 YCMK10TAA420-G21 CN E
MC475YC 475  380  433  346 YCMJ12TAA515-G21 CN E
MC503YC 503  402  456  365 YCMJ12540-G33 CN ECU
MC551YC 551  441  501  401 YCT16TAA600-G21 CN E
MC606YC 606  485  551  441 YCT16TAA660-G21 CN E
MC715YC 715  572  650  520 YCTD20780-G33 CN ECU
MC770YC 770  616  701  561 YCTD20840-G33 CN ECU
MC864YC 864  691  785  628 YCTD20940-G32 CN ECU
MC935YC 935  748  850  680 YCTD201020-G32 CN ECU
MC984YC 984  787  894  715 YCTH281070-G33 CN ECU
MC1121YC 1121  897  1019  815 YCTH281220-G33 CN ECU
MC1238YC 1238  990  1125  900 YCTH281350-G33 CN ECU
MC1238YC 1238  990  1125  900 YCTD40TA1350-G32 CN ECU
MC1375YC 1375  1100  1250  1000 YCTD40TA1500-G32 CN ECU
MC1540YC 1540  1232  1400  1120 YCTD40TA1680-G32 CN ECU
MC1705YC 1705  1364  1550  1240 YCTD40TA1860-G32 CN ECU
MC1900YC 1900  1520  1725  1380 YCTD40TA2070-G32 CN ECU
MC2090YC 2090  1672  1900  1520 YCTD52TA2270-G32 CN ECU
MC2313YC 2313  1850  2100  1680 YCTD52TA2510-G32 CN ECU
MC2481YC 2481  1985  2256  1805 YCTD52TA2700-G32 CN ECU

MORE SPEC. CONTACT US...

Genset Workshop

Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup
Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup
Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction BackupIndustrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction BackupIndustrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup

Industrial Genset 2500kVA Containerized Yuchai Diesel Generator for Construction Backup

FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.



-----------------------------------------------------------------------------------------------MAINTENANCE---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier