60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center

Product Details
Customization: Available
After-sales Service: Responsible
Warranty: 12 Months/1000 Hours Maintenance
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (24)
  • 60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center
  • 60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center
  • 60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center
  • 60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center
  • 60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center
  • 60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Genset Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MC
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Mtu
Alternator Brand
Stamford/Leroy Somer/Marathon/Mecca, Optional
Control Panel
Deepsea/Comap/Deif/Smartgen, Optional
Color
Customized
Canopy Type
Silent Sound Proof/Containerized/Open
Frequency(Hz)
50Hz/60Hz, 1500rpm 1800rpm
Voltage Output
230/400V, 220-480V
Power Generators
Prime Power/Standby Power/Continues Operation
Application
Data Center/Building/Power Plant/Construction
Accessory
Tool Kit, General Introduction Manual
Governing Type
Mech./Elec.
Service Coverage
Global Service
Certificate Available
CE, ISO, OEM Authorization etc.
Electric Generator
Diesel Generator Sets
Containerized Generator
Mtu 2500kVA Generator
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
85021
Production Capacity
1000/Year

Packaging & Delivery

Package Size
452.00cm * 213.00cm * 217.00cm
Package Gross Weight
5829.000kg

Product Description

Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled. As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, Deutz, MTU, Doosan,Mitsubishi, Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc.

Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in Data Centers, Telecom, Power Plant, Mining, Buildings, Constructions, Oil Gas,etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America. 

60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center
Product Description
60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center
60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center

60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center

Specification
Powered by  MTU                                                                                                                                                     50HZ  220-440 V 500-3600KVA 
Model LTP PRP Engine Fuel Cons. Cyl. Disp. Gov.
Dimention
Weight
KVA / KW  KVA/KW  Model Origin L/H(100%) L L*W*H (MM) KGS
MC660M 660  528  600  480 12V1600G10F IN 117.0 12V 21 ECU 3600*1604*2121 4529
MC729M 729  583  663  530 12V1600G20F IN 141.0  12V 21 ADEC 3737*1899*2137 5249
MC825M 825  660  750  600 12V1600G11F IN 157.7  12V 22.44 ECU 3630*2060*2525 5700
MC880M 880  704  800  640 12V1600G21F IN 167.6  12V 22.44 ECU 3630*2060*2525 5700
MC990M 990  792  900  720 12V1600G31F IN 185.9  12V 22.44 ECU 3630*2060*2525 5700
MC880M 880 704  800 640  12V2000G65 CN 184.0 12V 23.9 ADEC 4100*1810*2130 6100
MC1000M 1000 800  900 720  16V2000G25 CN 210.0 16V 31.8 ADEC 4495*2122*2295 7000
MC1100M 1100 880  1000 800  16V2000G65 CN 230.8 16V 31.8 ADEC 4495*2122*2295 7150
MC1250M 1250 1000  1125 900  18V2000G65 CN 264.5 16V 31.8 ADEC 4840*1825*2165 8000
MC1375M 1375 1100  1250 1000  18V2000G26F CN 261.1 18V 35.8 ADEC 4840*1825*2165 8100
MC1815M 1815 1452  1650 1320 12V4000G23F CN 338.1 12V 57.2 ADEC 6350*2150*2500 12500
MC2021M 2021 1617  1837.5 1470 12V4000G63F CN 373.1 12V 57.2 ADEC 6350*2150*2500 13000
MC2300M 2300 1840  2087.5 1670 16V4000G23F CN 428.1 16V 76.3 ADEC 7085*2250*2500 14500
MC2475M 2475 1980  2250 1800 16V4000G63F CN 465.5 16V 76.3 ADEC 7085*2250*2500 15000
MC2750M 2750 2200  2500 2000 20V4000G23F CN 521.2 20V 95.4 ADEC 7160*2555*2930 20500
MC3080M 3080 2464  2800 2240 20V4000G63F CN 567.5 20V 95.4 ADEC 7160*2555*2930 21000
MC3300M 3300 2640  3000 2400 20V4000G63LF CN 610.5 20V 95.4 ADEC 7160*2555*2930 21000
MC500M 500 400  450 360  10V1600G10F DE 101.3 10V 17.5 ADEC 3225*1485*2070 3850
MC550M 550 440  500 400  10V1600G20F DE 110.9 10V 17.5 ADEC 3225*1485*2070 3870
MC660M 660 528  600 480  12V1600G10F DE 131.7 12V 21 ADEC 3387*1531*2140 4890
MC700M 700 560  644 515  12V2000G25 DE 140.0 12V 23.9 ADEC 4100*1810*2130 6100
MC725M 725 580  660 528  12V1600G20F DE 144.9 12V 21 ADEC 3387*1531*2140 3784
MC1512M 1512 1210  1375 1100 12V4000G14RF DE 307.6 12V 57.2 ADEC 6150*2150*2500 12000
MC1815M 1815 1452  1650 1320 12V4000G14F DE 351.5 12V 57.2 ADEC 6350*2150*2500 12500
MC2020M 2020 1616  1837.5 1470 12V4000G24F DE 398.2 12V 57.2 ADEC 6350*2150*2500 13000
MC2300M 2300 1840  2087.5 1670 16V4000G14F DE 452.1 16V 76.3 ADEC 7085*2250*2500 14500
MC2500M 2500 2000  2250 1800 16V4000G24F DE 491.6 16V 76.3 ADEC 7085*2250*2500 15000
MC2750M 2750 2200  2500 2000 20V4000G14F DE 561.8 20V 95.4 ADEC 7160*2555*2930 20500
MC3080M 3080 2464  2800 2240 20V4000G24F DE 611.6 20V 95.4 ADEC 7160*2555*2930 21000
MC3300M 3300 2640  3000 2400 20V4000G34F DE 651.2 20V 95.4 ADEC 7160*2555*2930 21000
MC3600M 3600 2880  3250 2600 20V4000G44F DE 653.0 20V 95.4 ADEC 7160*2555*2930 21000
Powered by  MTU                                                                                                                                                 60HZ  110-480V 625-4000KVA 
Model LTP PRP Engine Fuel Cons. Cyl. Disp. Gov. Dimention Weight
KVA / KW  KVA/KW  Model Origin L/H(100%) L L*W*H (MM) KGS
MC875M 875 700 800 640 12V2000G45 CN 179.6 12V 23.9 ADEC 4100*1810*2130 6100
MC1000M 1000 800 900 720 12V2000G85 CN 196.9 12V 23.9 ADEC 4100*1810*2130 6900
MC1125M 1125 900 1025 820 16V2000G45 CN 219.2 16V 31.8 ADEC 4495*2122*2295 7000
MC1250M 1250 1000 1138 910 16V2000G85 CN 240.8 16V 31.8 ADEC 4495*2122*2295 7150
MC1500M 1500 1200 1375 1100 18V2000G85 CN 281.1 18V 35.8 ADEC 4840*1825*2165 8200
MC688M 688  550  625  500 12V1600G10S IN 132.5 12V 21 ADEC 3737*1899*2137 4890 
MC756M 756  605  688  550 12V1600G20S IN 140.0  12V 21 ADEC 3737*1899*2137 4890 
MC935M 935  748  850  680 12V1600G21S IN 174.8 12V 22.44 ADEC 4521*2135*2179  5829 
MC1004M 1004  803  913  730 12V1600G31S IN 186.7 12V 22.44 ADEC 4521*2135*2179  5829 
MC1121M 1121  897  1019  815 12V1600G41S IN 207.5 12V 22.44 ADEC 4521*2135*2179  5829 
MC625M 625 500 563 450 10V1600G20S DE 114.1 10V 17.5 ADEC 3225*1485*2070 3870
MC688M 688 550 625 500 12V1600G10S DE 135.5 12V 21 ADEC 3387*1531*2140 4890
MC750M 750 600 688 550 12V1600G20S DE 145.2 12V 21 ADEC 3387*1531*2140 4890
MC2000M 2000 1600 1819 1455 12V4000G43 DE 348.2 12V 57.2 ADEC 6150*2150*2500 12500
MC2200M 2200 1760 2000 1600 12V4000G83 DE 405.7 12V 57.2 ADEC 6350*2150*2500 13000
MC2500M 2500 2000 2250 1800 16V4000G43 DE 469.8 16V 76.3 ADEC 7085*2250*2500 14500
MC2875M 2875 2300 2625 2100 16V4000G83 DE 535.5 16V 76.3 ADEC 7085*2250*2500 15000
MC3125M 3125 2500 2875 2300 20V4000G43 DE 598.8 20V 95.4 ADEC 7160*2555*2930 20500
MC3438M 3438 2750 3125 2500 20V4000G83 DE 651.7 20V 95.4 ADEC 7160*2555*2930 21000
MC4000M 4000 3200 3637.5 2910 20V4000G83L DE 693.9 20V 95.4 ADEC 7160*2555*2930 21000
MORE DETAILED SPEC. CONTACT US...
 
Genset Workshop

60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center60Hz 110-480V 600-4000kVA 500-3200kw Containerized Generators Powered by Mtu Diesel Engine for Construction/Mining/Data Center

FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.


Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.

CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling. 
All items from following are seperately packed without connection.
 
SKD:Semi Knock Down Generator
Partially assembled generator. 
Part of the following items you choose will be assembled.
 

-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Send your message to this supplier