Customization: | Available |
---|---|
After-sales Service: | Responsible |
Warranty: | 12 Months or 1200 Operation Hours |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MECCA POWER Generator 1000kw 1200kw 1600kw 1800kw 2000kw 2200kw 3000kw 1000kva 1250kVA 1375kVA 1500kVA 2250kVA 2500kVA with Cummins/Mitsubishi/SME/Mtu/Baudouin/Perkins Diesel Engine with Leroy Somer/Stam*ford Alternator
Application:Power Plant/Data Center/Construction/Building Standby/Mining/Oil Gas field
MECCA POWER Mitsubishi/SME specification for your reference... MORE INFO CONTACT US...
Powered by Mitsubishi/SME 50HZ 400/230 V 8-2500KVA | ||||||||||||
Model | LTP | PRP | Engine | Fuel Cons. | Cyl. | Disp. | Gov. | Dimention | Weight | |||
KVA / KW | KVA/KW | Model | Origin | L/H(100%) | L*W*H (MM) | KGS | ||||||
MC688MS | 688 | 550 | 625 | 500 | S6R2-PTA-C | CN | 139 | 6L | 30.0 | E | 3770*1400*2000 | 6140 |
MC825MS | 825 | 660 | 750 | 600 | S6R2-PTAA-C | CN | 170 | 6L | 30.0 | E | 4100*1400*2150 | 6410 |
MC1375MS | 1375 | 1100 | 1250 | 1000 | S12R-PTA-C | CN | 266 | 12V | 49.0 | E | 4880*2000*2380 | 10560 |
MC1540MS | 1540 | 1232 | 1400 | 1120 | S12R-PTA2-C | CN | 281 | 12V | 49.0 | E | 4980*2000*2380 | 10660 |
MC1650MS | 1650 | 1320 | 1500 | 1200 | S12R-PTAA2-C | CN | 308 | 12V | 49.0 | E | 4980*2200*2380 | 10860 |
MC1915MS | 1915 | 1532 | 1750 | 1400 | S16R-PTA-C | CN | 310 | 16V | 65.4 | E | 5490*2190*2495 | 11410 |
MC2100MS | 2100 | 1680 | 1875 | 1500 | S16R-PTA2-C | CN | 418 | 16V | 65.4 | E | 5640*2170*2495 | 11710 |
MC2250MS | 2250 | 1800 | 2050 | 1640 | S16R-PTAA2-C | CN | 432 | 16V | 65.4 | E | 5820*2210*2670 | 13500 |
MC2500MS | 2500 | 2000 | 2250 | 1800 | S16R2-PTAW-C | CN | 476 | 16V | 79.9 | E | 6790*2200*2525 | 16400 |
MC825MT | 825 | 660 | 750 | 600 | S6R2-PTAA | JP | 170 | 6L | 30.0 | E | 4100*1400*2150 | 6410 |
MC880MT | 880 | 704 | 800 | 640 | S12A2-PTA | JP | 174 | 12V | 33.9 | E | 4350*1900*2310 | 6410 |
MC1100MT | 1100 | 880 | 1000 | 800 | S12H-PTA | JP | 220 | 12V | 37.1 | E | 4880*2000*2380 | 9860 |
MC1400MT | 1400 | 1120 | 1250 | 1000 | S12R-PTA | JP | 266 | 12V | 49.0 | E | 4880*2000*2380 | 10560 |
MC1540MT | 1540 | 1232 | 1400 | 1120 | S12R-PTA2 | JP | 281 | 12V | 49.0 | E | 4980*2000*2380 | 10660 |
MC1650MT | 1650 | 1320 | 1500 | 1200 | S12R-PTAA2 | JP | 308 | 12V | 49.0 | E | 4980*2200*2380 | 10860 |
MC1915MT | 1915 | 1532 | 1750 | 1400 | S16R-PTA | JP | 310 | 16V | 65.4 | E | 5490*2190*2495 | 11410 |
MC2100MT | 2100 | 1680 | 1875 | 1500 | S16R-PTA2 | JP | 418 | 16V | 65.4 | E | 5640*2170*2495 | 11710 |
MC2250MT | 2250 | 1800 | 2050 | 1640 | S16R-PTAA2 | JP | 432 | 16V | 65.4 | E | 5820*2210*2670 | 13500 |
MC2500MT | 2500 | 2000 | 2250 | 1800 | S16R2-PTAW | JP | 476 | 16V | 79.9 | E | 6790*2200*2525 | 16400 |
MC2750MT | 2750 | 2200 | 2500 | 2000 | S16R2-PTAW-E | JP | 528 | 16V | 79.9 | E | 7230*3064*3762 | 20000 |
Genset Main Technical Data | ||||||||||||||||||
Genset Model | MC688SME-MC2750MT | |||||||||||||||||
Prime Power | 600kW-1640kW | |||||||||||||||||
Standby Power | 660KW-1800kW | |||||||||||||||||
Frequency/Speed | 50Hz/1500rpm | |||||||||||||||||
Standard Voltage | 400V, Others as Application Requested | |||||||||||||||||
Phases | Three phases, four wires | |||||||||||||||||
Dimensions(L×W×H)mm | Open/Silent dimension as below list | |||||||||||||||||
100% Fuel Cons. (L/H) | 3.9~77.6 | |||||||||||||||||
Base Fuel tank (hour) | 8~10 |
Alternator Specifications | ||||||||||||||||||
Alternator Model | STAM*FORD TAL/PI/UCI/HCI/LVI Series | |||||||||||||||||
Output power | 600kW-1640kW | |||||||||||||||||
Voltage control | AVR | |||||||||||||||||
Number of phase | 3 | |||||||||||||||||
Power factor (Cos Phi) | 0.8 | |||||||||||||||||
Insulation Class | H | |||||||||||||||||
Number of Wires | 6 | |||||||||||||||||
Protection | 23 | |||||||||||||||||
Altitude | ≤ 1000 m | |||||||||||||||||
Number of Pole | 4 | |||||||||||||||||
Exciter type | AREP | |||||||||||||||||
Voltage regulation | ±0.5% | |||||||||||||||||
Totale Harmonic distortion | at no load < 4 % - on load < 4 % | |||||||||||||||||
Bearing | Single | |||||||||||||||||
Coupling | Direct |
Alternator Data | ||||||||||||||||||
♦ Operate either 50Hz or 60Hz. | ♦Stator grease insulation covered | |||||||||||||||||
♦ Standard enclosure IP23, but IP44, IP55 for option | ♦Rotator and excitation high polymer | |||||||||||||||||
♦ Insulation class H. | ♦ Resist the corruption oil and acid | |||||||||||||||||
♦ Shunt excitataion systems. | ♦Rotator balance is in accordance with BS5625 | |||||||||||||||||
♦ AREP or PMG system for options. | standard 12.5 | |||||||||||||||||
♦ Automatic voltage regulator | ♦High-quality lubrication sealed long-time bearing | |||||||||||||||||
♦ Single bearing alternator | ♦Rotator silicon steel close tight |
Payment Terms:
By telegraphic transfer: 30% deposit on signing of sales contract; and balance 70% before dispatch.
Delivery:
Approximately 2-4 weeks upon order confirmation.
Service Guarantee:
Before Service: According to the clients' requirement and actual situation, we will furnish the technology consultation and kinds of information.
After Service: Guarantee for one year or 1200 running hours (accord to whichever reach first) from installed date.
During the guarantee period, we will provide the free easy-damaged spare-parts for problems caused by our quality of production or raw material, except the damageable spare parts of diesel engine caused by customer's incorrect man-made operation. After checking, our company provides cost spare-parts maintenance for gensets .
Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.
CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling.
All items from following are seperately packed without connection.
SKD:Semi Knock Down Generator
Partially assembled generator.
Part of the following items you choose will be assembled.
Advantage:
Prompt delivery
Reduced tax to win more competition
Lower transportation fees to save cost
Localized production to win more tenders.
Increased production to offer more job opportunity for the government
Item |
Service |
Option |
Delivery Time |
1 | Engine | Doosan, Mtu, Mitsubishi, SME, Volvo, Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect. Marine and industry use Diesel, gas |
2-45days |
2 | Alternator | Stam*ford, Leroysomer, Meccalte, Marathon and customer requested alternators Medium and high voltage, Marine and industry use High IP Grade CT Drop kits, PMG, AVR |
2-15 days |
3 | Radiator | Fast, Beworld brand Original Radiator come with engine Local made radiator with authorization by engine supplier |
2-7days |
4 | Canopies | Powder coated and form mounted canopy,completely break down with hings, locks, raincap,bolts,screws, etc. Exhaust pipe and flanges Standard silent type canopy package Denyo type canopy package Rental type canopy package Telecom type canopy package Super silent type canopy package Containerized type canopy package Customerized type canopy package |
10days |
5 | Base frame | Standard base or simple iron base Anti-Vibration mountings With/without tank, base tank volume no limited Fuel gauges and high pressure fuel pipes |
3days |
6 | Control system | Controller: ComAp, DeepSea, Datacom, SmartGen etc. Breaker:Delixi,ABB, Chint, etc. Battery switch, battery charger, emergency stop botton, indicator, meters, CT and all wiring and harness. Batteries and cables Speed & lub oil & water temp sensors, A package of standard parts for assembly |
3days |
7 | Exhaust System | Industrial and residential silencer Flexible connects and elbow |
3days |
8 | Others |
Special demands |
Icon | Indicator Light | Reason | Fault Analysis |
Low oil pressure alarm |
Low oil pressure alarm |
When oil pressure does not reduce normally, the light is on. |
-General because of a lack of oil or lubrication system failure caused by (refueling or replacing the oil filter) -When occurs this fault should automatically shutdown generator sets immediately. |
High water temperature alarm |
High water temperature alarm |
When the water temperature has risen to a level higher than or equal to the sensor setting, the light is on. |
-General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Low fuel level alarm |
Low fuel level alarm |
When a fuel level has been detected by the sensor fitted to the daily tank, the light is on. |
-General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Battery charger fault alarm |
Battery charger fault alarm |
If the charging system has fault, when engine running, the light is off. |
-Battery charging system fault caused. -The light is on at the initial start, when the charger reaches a certain speed, the light is off. -This failure will not lead to automatic shutdown generating units. |
Crank failure alarm |
Crank failure alarm |
When the generator set failed three times (or six times) in a row starting, the light is on. |
-Oil supply system or re-start the system failure caused. |
Overload or breaker tripping alarm |
Overload or breaker tripping alarm |
When overloading or Short circuit, the light is on. Tripping circuit breakers cause generator set load out. |
-In this fault, it need to load or unload some parts to eliminate short-circuit, and then re-close the circuit breaker. |