Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type

Product Details
Customization: Available
After-sales Service: Responsible
Warranty: 12 Months/1000 Hours Maintenance
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (21)
  • Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
  • Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
  • Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
  • Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
  • Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
  • Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
Find Similar Products
  • Overview
  • Generator Introduction
  • Specification
  • Genset Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MCP
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Cn/UK/USA/in Perkins
Alternator Brand
Stamford/Leroy Somer/Marathon/Mecca
Control Panel
Deepsea/Comap/Datakom/Delixi/Smartgen and Others
Color
Optional
Canopy Type
Silent Sound Proof/Anti-Rusted Proof/Container
Frequency(Hz)
50Hz/60Hz
Voltage Output
230/400V, Others as Application Requested
Application
Standby/Hospital/Construction/Emergency
Accessory[a]
Spare Parts Document
Diesel Generators Factory
Perkins Power Generation Genset
Governing Type
Mech/Elec/ECU/Ecm/Hpcr/Adec
Service Coverage
Global Service
ATS
as Application Requested
Certificate Available
CE, ISO, OEM Authorization etc.
Soundless Generator
Diesel Powered Generator Sets
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
85021100
Production Capacity
1000/Year

Product Description

Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. 

Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
Generator Introduction

MECCA POWER EPA 6-600KVA PerkinsDiesel Power Generator, the perfect solution for all your power needs. This generator is designed to provide reliable and efficient power in any situation. Whether you need it for residential, commercial, or industrial use, this generator has got you covered.

Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open TypeMecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type
VIEW MORE PRODUCTS CLIK HERE...
Specification
Powered by  Perkins                                                                                                                50HZ:220-440V    10-2500KVA 
Model LTP PRP Engine Fuel Cons.L/H
(100%)
Cylinder Displacement
KVA / KW  KVA/KW  Model Origin L
MC10P 10 9 7 403A-11G1 CN/UK 2.6 3L 1.1
MC10P 10 9 7 403D-11G CN 2.6 3L 1.1
MC14P 14 11  13 10 403A-15G1 CN 3.7 3L 1.5
MC14P 14 11  13 10 403D-15G CN 3.7 3L 1.5
MC16P 16 13  15 12 403A-15G2 CN 4.32 3L 1.5
MC23P 23 18  20 16 404A-22G1 CN 5.3 4L 2.2
MC23P 23 18  20 16 404D-22G CN 5.3 4L 2.2
MC30P 30 24 28 22 404D-22TG CN 7.1 4L 2.2
MC33P 33 26  30 24 1103A-33G UK/IN 7.2 3L 3.3
MC50P 50 40  45 36 1103A-33TG1 UK/IN 7.2 3L 3.3
MC66P 66 53  60 48 1103A-33TG2 UK/IN 14.6 3L 3.3
MC72P 72 57  65 52 1104A-44TG1 CN 14.8 4L 4.4
MC88P 88 70  80 64 1104C-44TAG1 CN 18.6 4L 4.4
MC88P 88 70  80 64 1104A-44TG2 CN 18.7 4L 4.4
MC113P 113 90  100 80 1104C-44TAG2 CN 26.9 4L 4.4
MC150P 150 120  135 108 1106A-70TG1 CN 29.9 6L 7
MC165P 165 132  150 120 1106A-70TAG2 CN 33.4 6L 7
MC200P 200 160  180 144 1106A-70TAG3 CN 41.6 6L 7
MC220P 220 176  200 160 1106A-70TAG4 CN 45.8 6L 7
MC220P 220 176  200 160 1206A-E70TTAG1 UK 45.8 6L 7
MC250P 250 200  225 180 1506A-E88TAG2 USA 48.6 6L 8.8
MC250P 250 200  225 180 1206A-E70TTAG2 UK 51 6L 7
MC275P 275 220  250 200 1206A-E70TTAG3 UK 56.9 6L 7
MC339P 339 271  306 245 1706A-E93TAG1 USA 62.5 6L 9.3
MC383P 383 306  348 278 1706A-E93TAG2 USA 70.4 6L 9.3
MC275P 275 220  250 200 1506A-E88TAG3 USA 55.5 6L 8.8
MC330P 330 264  300 240 1506A-E88TAG5 USA 64.9 6L 8.8
MC400P 400 320  350 280 2206C-E13TAG2 USA 75 6L 12.5
MC450P 450 360  400 320 2206C-E13TAG3 USA 85 6L 12.5
MC500P 500 400  450 360 2506C-E15TAG1 USA 99 6L 15
MC550P 550 440  500 400 2506C-E15TAG2 USA 106 6L 15
MC660P 660 528  600 480 2806C-E18TAG1A USA 123 6L 18.1
MC715P 715 572  650 520 2806A-E18TAG2 USA 132 6L 18.1
MC825P 825 660  750 600 4006-23TAG2A UK/IN 155 6L 22.9
MC880P 880 704  800 640 4006-23TAG3A UK/IN 172 6L 22.9
MC1000P 1000 800  900 720 4008TAG1A UK/IN 195 8L 30.5
MC1100P 1100 880  1000 800 4008TAG2A UK/IN 215 8L 30.5
MC1100P 1100 880  1000 800 4008TAG2 UK/IN 224 8L 30.5
MC1250P 1250 1000  1125 900 4008-30TAG3 UK/IN 244 8L 30.5
MC1375P 1375 1100  1250 1000 4012-46TWG2A UK/IN 259 12L 45.8
MC1500P 1500 1200  1350 1080 4012-46TWG3A UK/IN 283 12L 45.8
MC1650P 1650 1320  1500 1200 4012-46TAG2A UK/IN 310 12L 45.8
MC1875P 1875 1500  1688 1350 4012-46TAG3A UK/IN 370 12L 45.8
MC2000P 2000 1600  1850 1480 4016TAG1A UK/IN 383 16L 61.1
MC2250P 2250 1800  2000 1600 4016TAG2A UK/IN 434 16L 61.1
MC2500P 2500 2000  2250 1800 4016-61TRG3 UK/IN 470 16L 61.1
MORE DETAILED SPEC. CONTACT US...
Genset Workshop

Mecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open TypeMecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open TypeMecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open TypeMecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open TypeMecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open TypeMecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open TypeMecca Power EPA Certified Perkins Diesel Generator 6-600kVA Silent and Open Type

FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.

 

Item
 

Service
 

Option
 

Delivery Time
 
1 Engine Doosan, Mtu, Mitsubishi, SME,  Volvo, 
Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect.
Marine and industry use 
Diesel, gas
2-45days
2 Alternator Stamford, Leroysomer,  Meccalte,  Marathon  and 
customer requested alternators
Medium and high voltage, 
Marine and industry use 
High IP Grade
CT Drop kits, PMG, AVR
2-15 days
3 Radiator Fast, Beworld brand
Original Radiator come with engine
Local made radiator with authorization by engine supplier
2-7days
4 Canopies Powder coated and form mounted canopy,completely break down with hings,
locks, raincap,bolts,screws, etc.
Exhaust pipe and flanges 
Standard silent type canopy package 
Denyo type canopy package 
Rental type canopy package 
Telecom type canopy package 
Super silent type canopy package 
Containerized type canopy package 
Customerized type canopy package
10days
5 Base frame Standard base or simple iron base
Anti-Vibration mountings
With/without tank, base tank volume no limited
Fuel gauges and high pressure fuel pipes
3days
6 Control system Controller: ComAp, DeepSea, Datacom, SmartGen etc.
Breaker:Delixi,ABB, Chint, etc.
Battery switch, battery charger, emergency stop botton, 
indicator, meters, CT and all wiring and harness.
Batteries and cables
Speed & lub oil & water temp sensors,
A package of standard parts for assembly
3days
7 Exhaust System Industrial and residential silencer
Flexible connects and elbow
3days
8
Others
 
Special demands  

-----------------------------------------------------------------------------------------------MAITAINENCE-------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.


Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Send your message to this supplier

*From: