• 10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
  • 10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
  • 10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
  • 10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
  • 10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
  • 10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant

10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant

After-sales Service: Responsible
Warranty: 12 Months or 1000 Operation Hours
Type: Self-Starting Diesel Generator
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant pictures & photos
10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
US $50,000-200,000 / SET
Min. Order: 1 SET
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Fujian, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (20)
  • Overview
  • Product Description
  • Specification
  • Genset Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MC
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Mtu/Cummins/Mitsubishi/Sme Series All Range
Control Panel
UK Deepsea/Comap/Smartgen/Deif
Cylinders
6-20 Cylinders
High Voltage
3.3kv/4.16kv/6kv/6.3kv/6.6kv/10kv/10.5kv/11kv/13.8
Frequency(Hz)
50Hz/60Hz, 1500prm/1800rpm
Application
Building/Power Plant/Construction/Data Center
Silent Diesel Generator
Weatherproof Containerized Generator
Diesel Generator Set
Electric Start Power Generator
Perkins Generator Set
Emergency Diesel Generator
Diesel Powered Generator
Container Generator for Outdoor Use
Industrial Generators
Diesel Electric Generator
Power Generator Set
Backup Diesel Generator Set
10MW Generator Set
Cop Diesel Generator Set
Certificate Available
CE, ISO, OEM Authorization etc.
Governing Type
Mech/Elec/ECU/Ecm/Adec/Hpcr
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
850211
Production Capacity
1000/Year

Packaging & Delivery

Package Size
7085.00cm * 2250.00cm * 2500.00cm
Package Gross Weight
15000.000kg

Product Description

Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.

With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. 

10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
Product Description

MECCA POWER 3.3KV-13.8KV high voltage gensets advantages of high output voltage and low output current make low power loss, long transmission distance and low comprehensive cost.
The simple system with less paralleled devices is easy to operate.Less fault points and low comprehensive cost.

This genset is designed with advanced fuel injection technology, making it more efficient than conventional genset. Domestic advanced technology and high-quality raw materials also provide a guarantee for the durability of high voltage generator. MECCA high voltage generators are high practicability, strong reliability, allowing long-term stable operation, safe and efficient,which are ideal for applications where power and efficiency are a top priority, such as large industrial settings,Data Centers,Power Plants,Constructions,Mining,etc.

10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
View more products click here...
Specification
Powered by  MTU                                                                                                                                                     50HZ  220-440 V   500-3600KVA 
Model LTP PRP Engine Fuel Cons. Cyl. Disp. Gov. Dimention Weight
KVA / KW  KVA/KW  Model Origin L/H(100%) L L*W*H (MM) KGS
MC880M 880 704  800 640  12V2000G65 CN 184.0 12V 23.9 ADEC 4100*1810*2130 6100
MC1000M 1000 800  900 720  16V2000G25 CN 210.0 16V 31.8 ADEC 4495*2122*2295 7000
MC1100M 1100 880  1000 800  16V2000G65 CN 230.8 16V 31.8 ADEC 4495*2122*2295 7150
MC1250M 1250 1000  1125 900  18V2000G65 CN 264.5 16V 31.8 ADEC 4840*1825*2165 8000
MC1375M 1375 1100  1250 1000  18V2000G26F CN 261.1 18V 35.8 ADEC 4840*1825*2165 8100
MC1815M 1815 1452  1650 1320 12V4000G23F CN 338.1 12V 57.2 ADEC 6350*2150*2500 12500
MC2021M 2021 1617  1837.5 1470 12V4000G63F CN 373.1 12V 57.2 ADEC 6350*2150*2500 13000
MC2300M 2300 1840  2087.5 1670 16V4000G23F CN 428.1 16V 76.3 ADEC 7085*2250*2500 14500
MC2475M 2475 1980  2250 1800 16V4000G63F CN 465.5 16V 76.3 ADEC 7085*2250*2500 15000
MC2750M 2750 2200  2500 2000 20V4000G23F CN 521.2 20V 95.4 ADEC 7160*2555*2930 20500
MC3080M 3080 2464  2800 2240 20V4000G63F CN 567.5 20V 95.4 ADEC 7160*2555*2930 21000
MC3300M 3300 2640  3000 2400 20V4000G63LF CN 610.5 20V 95.4 ADEC 7160*2555*2930 21000
MC500M 500 400  450 360  10V1600G10F DE 101.3 10V 17.5 ADEC 3225*1485*2070 3850
MC550M 550 440  500 400  10V1600G20F DE 110.9 10V 17.5 ADEC 3225*1485*2070 3870
MC660M 660 528  600 480  12V1600G10F DE 131.7 12V 21 ADEC 3387*1531*2140 4890
MC700M 700 560  644 515  12V2000G25 DE 140.0 12V 23.9 ADEC 4100*1810*2130 6100
MC725M 725 580  660 528  12V1600G20F DE 144.9 12V 21 ADEC 3387*1531*2140 3784
MC1512M 1512 1210  1375 1100 12V4000G14RF DE 307.6 12V 57.2 ADEC 6150*2150*2500 12000
MC1815M 1815 1452  1650 1320 12V4000G14F DE 351.5 12V 57.2 ADEC 6350*2150*2500 12500
MC2020M 2020 1616  1837.5 1470 12V4000G24F DE 398.2 12V 57.2 ADEC 6350*2150*2500 13000
MC2300M 2300 1840  2087.5 1670 16V4000G14F DE 452.1 16V 76.3 ADEC 7085*2250*2500 14500
MC2500M 2500 2000  2250 1800 16V4000G24F DE 491.6 16V 76.3 ADEC 7085*2250*2500 15000
MC2750M 2750 2200  2500 2000 20V4000G14F DE 561.8 20V 95.4 ADEC 7160*2555*2930 20500
MC3080M 3080 2464  2800 2240 20V4000G24F DE 611.6 20V 95.4 ADEC 7160*2555*2930 21000
MC3300M 3300 2640  3000 2400 20V4000G34F DE 651.2 20V 95.4 ADEC 7160*2555*2930 21000
MC3600M 3600 2880  3250 2600 20V4000G44F DE 653.0 20V 95.4 ADEC 7160*2555*2930 21000
Powered by CUMMINS G-DRRIVE Series                                                                  50HZ   220-440V 90-3750KVA 
Model LTP PRP Engine Emission
KVA / KW  KVA/KW  Model Origin
MC90C 90  72  82 66 QSB5-G3  US/UK S IIIA,Tier3
MC100C 100  80  91 73 QSB5-G4 US/UK S IIIA,Tier3
MC110C 110  88  100 80 QSB5-G5  US/UK S IIIA,Tier3
MC150C 150  120  136 109 QSB5-G6 US/UK S IIIA,Tier3
MC150C 150  120  137.5 110 QSB7-G2 US/UK S IIIA,Tier3
MC175C 175  140  150 120 QSB7-G3  US/UK S IIIA,Tier3
MC200C 200  160  180 144 QSB7-G4  US/UK S IIIA,Tier3
MC220C 220  176  200 160 QSB7-G5  US/UK S IIIA,Tier3
MC250C 250  200  225 180 QSL9-G2  US/UK S IIIA,Tier3
MC275C 275  220  250 200 QSL9-G3  US/UK S IIIA,Tier3
MC300C 300  240  275 220 QSL9-G4 US/UK S IIIA,Tier3
MC330C 330  264  300 240 QSL9-G5  US/UK N.A.
MC330C 330  264  300 240 QSL9-G7 US/UK S IIIA,Tier3
MC450C 450  360  400 320 QSX15-G4 US S II/Tier2
MC500C 500  400  455 364 QSX15-G6 US S II/Tier2
MC550C 550  440  500 400 QSX15-G8 US S II/Tier2
MC500C 500  400  455 364 QSX15-G13 US S IIIA,Tier3
MC550C 550  440  500 400 QSX15-G16 US S IIIA
MC700C 700  560  636 509 VTA28-G5 IN N.A.
MC825C 825 660  N.A. N.A. VTA28-G6 IN N.A.
MC800C 800  640  725 580 QSK23-G2 IN N.A.
MC810C 810  650  750 600 QSK23-G2 IN N.A.
MC880C 880  704  800 640 QSK23-G3  IN N.A.
MC900C 900  720  810 648 QSK23-G3  IN N.A.
MC813C 813  650  750 600 QSK23-G8 IN Tier2
MC900C 900  720  810 648 QSK23-G9 IN Tier2
MC1000C 1000 800  910 728 QST30-G3 US N.A.
MC1100C 1100 880  1000 800 QST30-G4 US N.A.
MC1000C 1000 800  910 728 KTA38-G3 IN N.A.
MC1132C 1132  906  1029 823 KTA38-G5 IN N.A.
MC1250C 1250 1000  N.A. N.A. KTA38-G9 IN N.A.
MC1250C 1250 1000  1135 908 QSK38-G2  UK Tier2
MC1375C 1375 1100  1250 1000 QSK38-G3 UK Tier2
MC1400C 1400  1120  1275 1020 QSK38-G5  UK Tier2
MC1400C 1400  1120  1275 1020 KTA50-G3 IN N.A.
MC1500C 1500  1200  1375 1100 KTA50-G8 IN N.A.
MC1675C 1650  1320  N.A. N.A. KTA50-G8 IN N.A.
MC1675C 1675  1340  1500 1200 KTA50-GS8 IN N.A.
MC1540C 1540  1232  1400 1120 QSK50-G3  UK/CN Tier2
MC1700C 1700  1360  1540 1232 QSK50-G4  UK/CN Tier2
MC1825C 1825  1460  1650 1320 QSK50-G7  UK/CN Tier2
MC2000C 2000  1600  1875 1500 QSK60-G3 UK/IN N.A.
MC2000C 2000  1600  1875 1500 QSK60-G7 UK/IN N.A.
MC2250C 2250  1800  2045 1636 QSK60-G4 UK/IN N.A.
MC2500C 2500  2000  2250 1800 QSK60-G8 UK/IN N.A.
MC2250C 2250  1800  2000 1600 QSK60-G11  UK/IN 4g TA
MC2500C 2500  2000  2000 1600 QSK60-G13  UK/IN 4g TA
MC2500C 2500  2000  2250 1800 QSK60-G21 UK/IN Tier2
MC2750C 2750  2200  2500 2000 QSK60-G23 UK/IN/CN T2
MC2750C 2750  2200  2500 2000 QSK78-G18 UK N.A.
MC3000C 3000  2400  2750 2200 QSK78-G9 UK N.A.
MC3000C 3000  2400  2750 2200 QSK78-G15 UK Tier 2
MC3300C 3300  2640  3000 2400 QSK95-G5 US 2g TA Luft
MC3500C 3500  2800  3125 2500 QSK95-G5 US 2g TA Luft
MC3760C 3760  3010  3360 2690 QSK95-G4 US N.A.
MC3750C 3750  3000  3350 2680 QSK95-G10 US Tier 2
MORE DETAILED INFO CONTACT US...
Genset Workshop

10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant

10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant10.5kv 11kv 13.8kv Medium High Voltage Generator Set 1000kVA-4000kVA Hv Generator with Cummins/Mtu Engine for Data Center/Power Plant
FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.





-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now