• Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
  • Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
  • Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
  • Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
  • Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
  • Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators

Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators

After-sales Service: Responsible
Warranty: 12 Months or 1200 Operation Hours
Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Fujian, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (20)

Basic Info.

Model NO.
MC
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Cummins/Perkins/Doosan/Deutz/Yanmar/Mitsubishi
Alternator Brand
Stamford/Marathon/Leroy Somer/Mecca, Optional
Control Panel
Deepsea/Comap/Datakom/Delixi/Smartgen, etc.
Phase
Single Phase/Three Phase
Canopy Type
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
Frequency(Hz)
50Hz/60Hz, 1500rpm 1800rpm
Voltage Output
230/400V, 220-480V
Application
Telecom/Commercial/Power Plant/Construction
Cylinder
Single/Two/Three Cylinder
Diesel Engine Generator
Doosan Diesel Generator
Governing Type
Mech/Elec/ECU/Ecm/Adec/Hpcr
ATS
Optional
Certificate Available
CE, ISO, OEM Authorization etc.
Maximun Permissible High Altitude
2500m
Power Generation
Generating Sets
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
85021100
Production Capacity
1000/Year

Product Description

Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.

With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. 

Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley GeneratorsMECCA POWER Trailer Type Diesel Generator Sets

(1) 2~8 wheels,optional;
(2) single or double bearing,
(3) front supporting regulating wheel,
(4) direction leading system,
(5) supporting leg,
(6) braking system,
(7) traffic light in the back,
(8) 
reflective traffic stickers.
Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
 
Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators

Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley GeneratorsMobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators

Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley GeneratorsMobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators
Payment Terms:
By telegraphic transfer: 30% deposit on signing of sales contract; and balance 70% before dispatch. 
                                
Delivery:
Approximately 2-4 weeks upon order confirmation.

Service Guarantee:
Before Service: According to the clients' requirement and actual situation, we will furnish the technology consultation and kinds of information.  

After Service: Guarantee for one year or 1200 running hours (accord to whichever reach first) from installed date.
During the guarantee period, we will provide the free easy-damaged spare-parts for problems caused by our quality of production or raw material, except the damageable spare parts of diesel engine caused by customer's incorrect man-made operation. After checking, our company provides cost spare-parts maintenance for gensets .  


Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.

CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling. 
All items from following are seperately packed without connection.
 
SKD:Semi Knock Down Generator
Partially assembled generator. 
Part of the following items you choose will be assembled.
 
Advantage:
Prompt delivery
Reduced tax to win more competition
Lower transportation fees to save cost
Localized production to win more tenders. 
Increased production to offer more job opportunity for the government

Item
 

Service
 

Option
 

Delivery Time
 
1 Engine Doosan, Mtu, Mitsubishi, SME,  Volvo, 
Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect.
Marine and industry use 
Diesel, gas
2-45days
2 Alternator Stamford, Leroysomer,  Meccalte,  Marathon  and 
customer requested alternators
Medium and high voltage, 
Marine and industry use 
High IP Grade
CT Drop kits, PMG, AVR
2-15 days
3 Radiator Fast, Beworld brand
Original Radiator come with engine
Local made radiator with authorization by engine supplier
2-7days
4 Canopies Powder coated and form mounted canopy,completely break down with hings,
locks, raincap,bolts,screws, etc.
Exhaust pipe and flanges 
Standard silent type canopy package 
Denyo type canopy package 
Rental type canopy package 
Telecom type canopy package 
Super silent type canopy package 
Containerized type canopy package 
Customerized type canopy package
10days
5 Base frame Standard base or simple iron base
Anti-Vibration mountings
With/without tank, base tank volume no limited
Fuel gauges and high pressure fuel pipes
3days
6 Control system Controller: ComAp, DeepSea, Datacom, SmartGen etc.
Breaker:Delixi,ABB, Chint, etc.
Battery switch, battery charger, emergency stop botton, 
indicator, meters, CT and all wiring and harness.
Batteries and cables
Speed & lub oil & water temp sensors,
A package of standard parts for assembly
3days
7 Exhaust System Industrial and residential silencer
Flexible connects and elbow
3days
8
Others
 
Special demands  

-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now