Resistive Inductive Loadbank 3000kVA 3150kVA 3750kVA Load Bank for Generator Test/Power Station
| Customization: | Available |
|---|---|
| After-sales Service: | Responsible |
| Warranty: | 12 Months or 1000 Operation Hours |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Find Similar Products
Basic Info.
- Model NO.
- MCLB
- Max Diameter of Workpiece
- 1200mm
- Mass Scope of Workpiece
- <900kg
- Type
- Universal Testing Machine
- Maxcapacity
- Power Loading Test
- Accuracy Grade
- 1
- Load Way
- Electronic Load
- Loading Method
- Static Load
- Display
- Digital
- Control
- Computer Control
- Weight
- >2000Kg
- Power Source
- 110V-20kv,50Hz 60Hz
- Oil Cylinder Position
- Test Machine
- Resistor
- Self-Developed
- Frequency
- 45-65Hz
- Protection
- Over-Temperature, Over-Current, Short Circuit
- Test Voltage
- 110V-20kv
- Adjustment
- Mini Step 1kw
- Control Method
- Manual/Automatic
- Load Bank
- Power Grid, Generator Sets, UPS, Inverters
- Load Bank for Sale
- Power Supply Testing Load Bank
- Accessory Option
- Remote Control, Touch Screen, Technical Sheet Expo
- Load Tolerance (Each Step )
- Plus or Minus 5% 3%
- Application
- Data Center/Industrial/Marine/Power Plants
- Application (a)
- Renewable Energy/Triple Switch/Offshore Platform
- Cooling
- Forced Air Cooling, Horizontal Inlet Air and Horiz
- Altitude
- Under 2500 Meters
- Resistor Alloy
- Nickel-Chromium Alloy(Nicr6023)
- Transport Package
- Container
- Specification
- 1000kW-6000KW
- Trademark
- MECCA BRAND
- Origin
- Fujian
- HS Code
- 90303390
- Production Capacity
- 1000/Year
Packaging & Delivery
- Package Size
- 606.00cm * 244.00cm * 259.00cm
- Package Gross Weight
- 8000.000kg
Product Description
With a wealth of load bank equipment solutions backed by exceptional service, Mecca Power Solutions service offering keeps us way ahead of the competition.
With facilities covering worldwide, we offer competitive and reliable load bank solutions on time and on budget. The load bank engineers can install the load bank equipment and provide full documentation and easy to interpret results.
Resistive /Reactive Load Bank
Resistive Reactive Load Bank is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems where rated kVA, rated power factor and rated current testing is required.
High Voltage Load Bank
The ability to test critical power systems at voltages of 1.2KV to 80kV using direct-connect, High Voltage Load Bank offers engineers flexibility, time savings, cost savings, space savings and simplicity.
Use our load bank to test:
- Diesel generators
- DC generators and power supplies
- Rectifiers
- Chillers
- Data Centre Power and Thermal Systems
- Air-Conditioning Systems
- Motors (starting systems)
- Frequency converters
- Electrical distribution panels and systems
- Uninterrupted Power Systems (UPS)
- Battery discharge
- Heat testing / server simulator test

MECCA POWER Containerized Load Banks for Generator Test / Power Grid!







| RESISTIVE LOAD BANK 50/60HZ 100-3000KW | |||||
| Model | Rated Power | Power Factor | Load Voltage | Dimension | Weight |
| (L*W*H)mm | (kg) | ||||
| MCLB-100 | 100kW | 1.0 | 3PH 380-480V (380V,400V,415V,440V,460V,480V OPTIONAL) |
540*292*604 | 35 |
| MCLB-200 | 200kW | 750*511*746 | 95 | ||
| MCLB-200 | 200kW | 748*517*726 | 85 | ||
| MCLB-250 | 250kW | 1440*1300*1070 | 550 | ||
| MCLB-500 | 500kW | 1100*900*1200 | 385 | ||
| MCLB-500 | 500kW | 1800*1300*1070 | 700 | ||
| MCLB-600 | 600kW | 1800*1420*1190 | 800 | ||
| MCLB-1000 | 1000kW | 1800 *1300*1918 | 1300 | ||
| MCLB-1250 | 1250kW | 2660*1600*2100 | 2000 | ||
| MCLB-1500 | 1500kW | 2400*1700*1800 | 1700 | ||
| MCLB-2000 | 2000kW | 4000*2100*2100 | 4500 | ||
| MCLB-2500 | 2500kW | 6058*2438*2591 | 7500 | ||
| MCLB-3000 | 3000kW | 6058*2438*2591 | 8000 | ||
| RESISTIVE INDUCTIVE LOAD BANK 50/60HZ 40KW-4800KW | |||||
| Model | Installed Capacity | Power Factor | Load Voltage | Dimension | Weight |
| W*D*H(mm) | (kg) | ||||
| MCLB-40 | R: 40kW | 0.8/1.0 | 3PH 380-480V (380V,400V,415V,440V,460V,480V OPTIONAL) |
1200*900*1350 | 150 |
| L: 30kVAr | |||||
| MCLB-100 | R: 100kW | 1860*1100*1450 | 375 | ||
| L: 75kVAr | |||||
| MCLB-800 | R: 800kW | 2440*1400*1680 | 3000 | ||
| L: 600kVAr | |||||
| MCLB-1200 | R: 1200kW | 6058*2438*2591 | 4500 | ||
| L: 900kVAr | |||||
| MCLB-1600 | R: 1600kW | 6058*2438*2591 | 6000 | ||
| L: 1200kVAr | |||||
| MCLB-2000 | R: 2000kW | 6058*2438*2591 | 7500 | ||
| L: 1500kVAr | |||||
| MCLB-2400 | R: 2400kW | 6058*2438*2591 | 9000 | ||
| L: 1800kVAr | |||||
| MCLB-2800 | R: 2800kW | 6058*2438*2591 | 10500 | ||
| L: 2100kVAr | |||||
| MCLB-3500 | R: 3500kW | 6058*2438*2591 | 13125 | ||
| L: 2625kVAr | |||||
| MCLB-4000 | R: 4000kW | 12192*2438*2591 | 15000 | ||
| L: 3000kVAr | |||||
| MCLB-4800 | R: 4800kW | 12192*2438*2591 | 18000 | ||
| L: 3600kVAr | |||||
| HIGH VOLTAGE LOAD BANK 50/60HZ 2000KW-6000KW | |||||
| Model | Installed Capacity | Power Factor | Load Voltage | Dimension | Weight(kg) |
| W*D*H(mm) | |||||
| MCLB-2000kW | 2000kW | 1 | 3 phase 3.3-11KV 50/60Hz | 6058*2438*2591 | 6000 |
| MCLB-3000kW | 3000kW | 6058*2438*2591 | 7000 | ||
| MCLB-5000kW | 5000kW | 12192*2438*2591 | 140000 | ||
| MCLB-6000kW | 6000kW | 12192*2438*2591 | 160000 | ||






1.Q: What is your MOQ of this item?
A:1 Set
2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight
3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.
4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples
5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.
6.Q:Do you offer OEM service?
A: Yes
7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva
8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Load Bank
- Resistive Inductive Loadbank 3000kVA 3150kVA 3750kVA Load Bank for Generator Test/Power Station