General Feature | ||||||||||||||||||
♦ Assembled by diesel engine and Brushless alternator. | ||||||||||||||||||
Three filters as standard, fuel and water separator as optional. | ||||||||||||||||||
♦ Radiator and fan with safety guard. | ||||||||||||||||||
♦ Single bearing alternator IP 23, Insulation Class H. | ||||||||||||||||||
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank. | ||||||||||||||||||
♦ Automatic control panel and 3 poles circuit breaker, internal cable. | ||||||||||||||||||
♦ 12V or 24V battery, battery wires. | ||||||||||||||||||
♦ Battery and float battery charger as standard supply scope. | ||||||||||||||||||
♦ Fuel level indicator in meter and panel | ||||||||||||||||||
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers. |
Icon | Indicator Light | Reason | Fault Analysis |
Low oil pressure alarm |
Low oil pressure alarm |
When oil pressure does not reduce normally, the light is on. |
-General because of a lack of oil or lubrication system failure caused by (refueling or replacing the oil filter) -When occurs this fault should automatically shutdown generator sets immediately. |
High water temperature alarm |
High water temperature alarm |
When the water temperature has risen to a level higher than or equal to the sensor setting, the light is on. |
-General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Low fuel level alarm |
Low fuel level alarm |
When a fuel level has been detected by the sensor fitted to the daily tank, the light is on. |
-General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Battery charger fault alarm |
Battery charger fault alarm |
If the charging system has fault, when engine running, the light is off. |
-Battery charging system fault caused. -The light is on at the initial start, when the charger reaches a certain speed, the light is off. -This failure will not lead to automatic shutdown generating units. |
Crank failure alarm |
Crank failure alarm |
When the generator set failed three times (or six times) in a row starting, the light is on. |
-Oil supply system or re-start the system failure caused. |
Overload or breaker tripping alarm |
Overload or breaker tripping alarm |
When overloading or Short circuit, the light is on. Tripping circuit breakers cause generator set load out. |
-In this fault, it need to load or unload some parts to eliminate short-circuit, and then re-close the circuit breaker. |