Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz

Product Details
Customization: Available
After-sales Service: Responsible
Warranty: 12 Months Warranty
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (21)
  • Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz
  • Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz
  • Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz
  • Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz
  • Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz
  • Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Genset Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MC
Mass Scope of Workpiece
<900kg
Type
Universal Testing Machine
Maxcapacity
Power Loading Test
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
>2000Kg
Power Source
220-480V
Oil Cylinder Position
Test Machine
Resistor
Self-Developed
Frequency
45-65Hz
Protection
Over-Temperature, Over-Current, Short Circuit
Input Voltage Tolerance
0.1V
Adjustment
1kw
Control Method
Manual/Automatic
Load Bank
AC Source, Generator Sets, UPS, Inverters, Chargin
Load Bank for Sale
Power Supply Testing Load Bank
Accessory Option
Remote Control, Touch Screen, Technical Sheet Expo
Load Tolerance (Each Step )
Plus or Minus 5% 3%
Application
Data Center/Industrial/Marine/Power Plants
Application (a)
Renewable Energy/Triple Switch/Offshore Platform
Cooling
Forced Air Cooling, Horizontal Inlet Air and Horiz
Altitude
Under 2500 Meters
Resistor Alloy
Nickel-Chromium Alloy(Nicr6023)
Transport Package
Wooden Boxes, Container
Specification
500kW-5MW, AC
Trademark
MECCA BRAND
Origin
Fujian
HS Code
90303390
Production Capacity
1000/Year

Packaging & Delivery

Package Size
400.00cm * 210.00cm * 210.00cm
Package Gross Weight
5000.000kg

Product Description

Resistive Load Bank

With a wealth of load bank equipment solutions backed by exceptional service, Mecca Power Solutions service offering keeps us way ahead of the competition.  
With facilities covering worldwide, we offer competitive and reliable load bank solutions on time and on budget.  The load bank engineers can install the load bank equipment and provide full documentation and easy to interpret results.


Resistive /Reactive Load Bank

Resistive Reactive Load Bank is the perfect solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems where rated kVA, rated power factor and rated current testing is required.

High Voltage Load Bank

The ability to test critical power systems at voltages of 1.2KV to 80kV using direct-connect, High Voltage Load Bank offers engineers flexibility, time savings, cost savings, space savings and simplicity.

Use our load bank to test:
  • Diesel generators
  • DC generators and power supplies
  • Rectifiers
  • Chillers
  • Data Centre Power and Thermal Systems
  • Air-Conditioning Systems
  • Motors (starting systems)
  • Frequency converters
  • Electrical distribution panels and systems
  • Uninterrupted Power Systems (UPS)
  • Battery discharge
  • Heat testing / server simulator test
  • Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz
Product Description

Mecca Power Load Bank is mainly used to test and maintain power generators.batteries, ups, switchgears, transformers, inverters, ground power units, auxiliary powerunits, ect

lt is applied for ships, oil, offshore platforms, data centers, telecom, finance, nuclearpower, mobile power stations, power plant security, rail transit, aviation, aero.space, renewable energy, smart grids, micro-grids, instrument switches, research andteaching, etc.

Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60HzOutdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60HzOutdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60HzOutdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60HzOutdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz
Specification
RESISTIVE LOAD BANK                                                                                                50/60HZ  100-3000KW
Model Rated Power Power Factor Load Voltage Dimension Weight
(L*W*H)mm (kg)
MCLB-100 100kW 1.0  3PH 380-480V
(380V,400V,415V,440V,460V,480V
OPTIONAL)
540*292*604 35
MCLB-200 200kW 750*511*746 95
MCLB-200 200kW 748*517*726 85
MCLB-250 250kW 1440*1300*1070 550
MCLB-500 500kW 1100*900*1200 385
MCLB-500 500kW 1800*1300*1070 700
MCLB-600 600kW 1800*1420*1190 800
MCLB-1000 1000kW 1800 *1300*1918  1300
MCLB-1250 1250kW 2660*1600*2100 2000
MCLB-1500 1500kW 2400*1700*1800 1700
MCLB-2000 2000kW 4000*2100*2100 4500
MCLB-2500 2500kW 6058*2438*2591 7500
MCLB-3000 3000kW 6058*2438*2591 8000
PS:The parameters is only for reference, pls contact supplier for exact information.
Genset Workshop

Outdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60HzOutdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60HzOutdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60HzOutdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60HzOutdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60HzOutdoor Use Container Type Load Bank 1MW 1300kw 2000kw for Power Grid 50Hz/60Hz

FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier