• 15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
  • 15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
  • 15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
  • 15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
  • 15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
  • 15kw Open Type Diesel Power Generator in 60Hz[Mbps02]

15kw Open Type Diesel Power Generator in 60Hz[Mbps02]

Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Output Type: AC Three Phase
Speed: Low Speed
Customization:

Contact Supplier

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
MCP
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Perkins UK in Cn
Alternator Brand
Stamford/Marathon/Mecca and Unique Brand for Usage
Control Panel
Deepsea/Comap/Datakom/Delixi/Smartgen and Others
Cylinders
4-20 Cylinders
Canopy Type
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
Frequency(Hz)
50Hz/60Hz or Adjusted Frequency Via Converter
Voltage Output
230/400V, Others as Application Requested
Application
Prime Power/Standby Power/Continues Operation
Warranty
12 Months or 1200 Operation Hours
Accessory[a]
a Suit of Ripple Flex Exhaust Pipe, Exhaust Siphon
Accessory[B]
Cummins Tool Kit, General Introduction Manual
Governing Type
Mech./Elec.
Service Coverage
Global Service
ATS
as Application Requested
Certificate Available
Ce, ISO, OEM Authorization etc.
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
85021100
Production Capacity
1000/Year

Product Description


15kw Open Type Diesel Power Generator in 60Hz[Mbps02]

Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators. Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.
Powered by  Perkins            50HZ  400/230 V 10-2500KVA 
Model LTP PRP Engine Fuel Cons. Cylinder Displacement Gov. Dimention Weight
KVA / KW  KVA/KW  Model Origin L/H(100%) L L*W*H (MM) KGS
MC10P 10 9 7.2 403A-11G1 CN/UK 3 3L 1.1 M 1370×750×1050 450 
MC10P 10 9 7.2 403D-11G CN/UK 2.6  3L 1.1 M 1370×750×1050 450 
MC15P 15 12  13 10 403A-15G1 CN/UK 3.7  3L 1.5 M 1370×750×1050 550 
MC15P 15 12  13 10 403D-15G CN/UK 3.6  3L 1.5 M 1400×750×1050 550 
MC16.5P 16.5 13  15 12 403A-15G2 CN/UK 4.3 3L 1.5 M 1400×750×1050 560 
MC22P 22 18  20 16 404A-22G1 CN/UK 5.3 4L 2.2 M 1510×750×1050 650 
MC22P 22 18  20 16 404D-22G CN/UK 5.3  4L 2.2 M 1510×750×1050 630 
MC30P 30 24 28 22 404D-22TG CN/UK 7.1  4L 2.2 E 1570×750×1050 700 
MC33P 33 26  30 24 1103A-33G UK/IN 7.1 3L 3.3 M 1670×750×1200 830 
MC50P 50 40  45 36 1103A-33TG1 UK/IN 10.7 3L 3.3 M 1750×750×1200 880 
MC66P 66 53  60 48 1103A-33TG2 UK/IN 13.9 3L 3.3 M 1820×750×1200 900 
MC72P 72 58  65 52 1104A-44TG1 CN/UK 14.8 4L 4.4 M 1960×750×1200 1080 
MC88P 88 70  80 64 1104A-44TG2 CN/UK 18.7 4L 4.4 M 1960×750×1200 1080 
MC88P 88 70  80 64 1104C-44TAG1 CN/UK 18.6  4L 4.4 E 2050×750×1270 1050 
MC110P 110 88  100 80 1104C-44TAG2 CN/UK 22.6 4L 4.4 E 2050×750×1270 1080 
MC150P 150 120  135 108 1106A-70TG1 CN/UK 29.9 6L 7 M 2230×760×1440 1600 
MC165P 165 132  150 120 1106A-70TAG2 CN/UK 33.4 6L 7 M 2280×820×1440 1600 
MC200P 200 160  180 144 1106A-70TAG3 CN/UK 41.6 6L 7 M 2400×820×1470 1750
MC220P 220 176  200 160 1106A-70TAG4 CN/UK 45.8 6L 7 E 2400×820×1470 1800
MC250P 250 200  225 180 1506A-E88TAG2 USA 48.6 6L 8.8 ECM 2550×950×1600 2430
MC275P 275 220  250 200 1506A-E88TAG3 USA 55.5 6L 8.8 ECM 2550×950×1600 2430
MC330P 330 264  300 240 1506A-E88TAG5 USA 65 6L 8.8 ECM 2650×1120×1600 2650
MC400P 400 320  350 280 2206C-E13TAG2 USA 71 6L 12.5 ECM 3060×1140×2000 3350
MC450P 450 360  400 320 2206C-E13TAG3 USA 81 6L 12.5 ECM 3100×1140×2000 3500
MC500P 500 400  450 360 2506C-E15TAG1 USA 95 6L 15.2 ECM 3250×1160×2030 3700
MC550P 550 440  500 400 2506C-E15TAG2 USA 100 6L 15.2 ECM 3350×1160×2030 3850
MC660P 660 528  600 480 2806C-E18TAG1A USA 123 6L 18.1 ECM 3230×1550×2050 4600
MC715P 715 572  650 520 2806A-E18TAG2 USA 132 6L 18.1 ECM 3340×1550×2050 4650
MC825P 825 660  750 600 4006-23TAG2A UK/IN 161 6L 22.9 E 4080×1700×2230 5550
MC880P 880 704  800 640 4006-23TAG3A UK/IN 172 6L 22.9 E 4080×1700×2230 5600
MC1000P 1000 800  900 720 4008TAG1A UK/IN 195 8L 30.6 E 4600×2040×2230 6600
MC1100P 1100 880  1000 800 4008TAG2A UK/IN 226 8L 30.6 E 4600×2040×2230 6650
MC1250P 1250 1000  1125 900 4008-30TAG3 UK/IN 244 8L 30.6 E 4500×2200×2230 7300
MC1375P 1375 1100  1250 1000 4012-46TWG2A UK/IN 259 12V 45.8 E 4900×2200×2530 7600
MC1500P 1500 1200  1350 1080 4012-46TWG3A UK/IN 283 12V 45.8 E 5000×2200×2530 7850
MC1650P 1650 1320  1500 1200 4012-46TAG2A UK/IN 200 12V 45.8 E 5000×2200×2530 8100
MC1850P 1850 1480  1650 1320 4012-46TAG3A UK/IN 370 12V 45.8 E 5200×2200×2530 10000
MC1875P 1875 1500  1705 1364 4012-46TAG3A UK/IN 370 12V 45.8 E 5200×2200×2530 10000
MC2030P 2030 1624  1845 1476 4016TAG1A UK/IN 383 16V 61.1 E 5750×2800×3300 10500
MC2260P 2260 1808  2050 1640 4016TAG2A UK/IN 434 16V 61.1 E 5750×2800×3300 10500
MC2500P 2500 2000  2250 1800 4016-61TRG3 UK/IN 473 16V 61.1 E 5700×2900×3120 11300
15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
15kw Open Type Diesel Power Generator in 60Hz[Mbps02] 15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
General Feature
♦ Assembled by diesel engine and Brushless alternator. 
 Three filters as standard, fuel and water separator as optional.
♦ Radiator and fan with safety guard.
♦ Single bearing alternator IP 23, Insulation Class H.
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank.
♦ Automatic control panel and 3 poles circuit breaker, internal cable.
♦ 12V or 24V battery, battery wires.
♦ Battery and float battery charger as standard supply scope.
♦ Fuel level indicator in meter and panel
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers. 
Genset Main Technical Data
Genset Model MC8C-MC2000C
Prime Power 8kW-2000kW
Standby Power 100KW-2200kW
Frequency/Speed 50Hz/1500rpm
Standard Voltage 230/400V, Others as Application Requested
Phases Three phases, four wires
Dimensions(L×W×H)mm Open/Silent dimension as below list
100% Fuel Cons. (L/H) 3.9~77.6
Base Fuel tank (hour) 8~10
Alternator Specifications
Alternator Model STAMFORD TAL/PI/UCI/HCI/LVI Series
Output power 8kW-2000kW
Voltage control AVR
Number of phase 3
Power factor (Cos Phi) 0.8
Insulation Class H
Number of Wires  6
Protection 23
Altitude  ≤ 1000 m
Number of Pole  4
Exciter type AREP
Voltage regulation ±0.5%           
Totale Harmonic distortion at no load < 4 % - on load < 4 %
Bearing   Single
Coupling Direct
Alternator Data
♦ Operate either 50Hz or 60Hz. ♦Stator grease insulation covered
♦ Standard enclosure IP23, but IP44, IP55 for option ♦Rotator and excitation high polymer
♦ Insulation class H.  ♦ Resist the corruption oil and acid
♦ Shunt excitataion systems. ♦Rotator balance is in accordance with BS5625  
♦ AREP or PMG system for options.  standard 12.5
♦ Automatic voltage regulator ♦High-quality lubrication sealed long-time bearing
♦ Single bearing alternator ♦Rotator silicon steel close tight
Standard Accessories
*Auto Control Panel *Starting Motor
*Main Ciruit Breaker *Exhaust silencer
*Fuel tank *Starting battery
*Base Frame *Float battery charger
*Filter  *Flange
15kw Open Type Diesel Power Generator in 60Hz[Mbps02]

With more than 10 years of experience in manufacturing and exporting energy products, as well as our sales and engineering group in the United States, the Mecca team will advise you on product choices.
most suitable generator units, for building, mining, telecommunications, rental, railway stations, power plants, data. Treatment centers, etc.

Mecca provides a permanent technical support service - supported by a team with more than 10 years of experience in the energy sector.
Our technical support service can be carried out remotely by telephone or via an on-site control camera. This service is available for all generators manufactured by Mecca and allows the customer a more direct contact (which will be hidden by the platform but you can check and compose it on our official website).

Mecca has a set of specific and dedicated equipment to assist and organize the generators. Whenever it is impossible to carry out repairs at the intervention site, repairs can be made at our facilities.
15kw Open Type Diesel Power Generator in 60Hz[Mbps02]


15kw Open Type Diesel Power Generator in 60Hz[Mbps02]

Customerized Fuel Tank


1.Volume: 500L, 1000L,1500L,2000L,3000L etc.

2.Plate steel construction

3.Fuel level meter

4.Fuel transfer systems

5.Double wall

6.Electric fuel pump 

7.Fuel level sensor (indicated on control module)

8.Fuel automatic filling system

9.Tank in genset base, top, built-in, seperately stand etc

15kw Open Type Diesel Power Generator in 60Hz[Mbps02]

Payment Terms:
By telegraphic transfer: 30% deposit on signing of sales contract; and balance 70% before dispatch. 
                                
Delivery:
Approximately 2-4 weeks upon order confirmation.

Service Guarantee:
Before Service: According to the clients' requirement and actual situation, we will furnish the technology consultation and kinds of information.  

After Service: Guarantee for one year or 1200 running hours (accord to whichever reach first) from installed date.
During the guarantee period, we will provide the free easy-damaged spare-parts for problems caused by our quality of production or raw material, except the damageable spare parts of diesel engine caused by customer's incorrect man-made operation. After checking, our company provides cost spare-parts maintenance for gensets .  


Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.

CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling. 
All items from following are seperately packed without connection.
 
SKD:Semi Knock Down Generator
Partially assembled generator. 
Part of the following items you choose will be assembled.
 
Advantage:
Prompt delivery
Reduced tax to win more competition
Lower transportation fees to save cost
Localized production to win more tenders. 
Increased production to offer more job opportunity for the government

Item
 

Service
 

Option
 

Delivery Time
 
1 Engine  Cummins, Doosan, Mtu, Mitsubishi, SME, Scania, Volvo, 
Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect.
Marine and industry use 
Diesel, gas
2-45days
2 Alternator Stamford, Leroysomer,  Meccalte,  Marathon  and 
customer requested alternators
Medium and high voltage, 
Marine and industry use 
High IP Grade
CT Drop kits, PMG, AVR
2-15 days
3 Radiator Fast, Beworld brand
Original Radiator come with engine
Local made radiator with authorization by engine supplier
2-7days
4 Canopies Powder coated and form mounted canopy,completely break down with hings,
locks, raincap,bolts,screws, etc.
Exhaust pipe and flanges 
Standard silent type canopy package 
Denyo type canopy package 
Rental type canopy package 
Telecom type canopy package 
Super silent type canopy package 
Containerized type canopy package 
Customerized type canopy package
10days
5 Base frame Standard base or simple iron base
Anti-Vibration mountings
With/without tank, base tank volume no limited
Fuel gauges and high pressure fuel pipes
3days
6 Control system Controller: ComAp, DeepSea, Datacom, SmartGen etc.
Breaker:Delixi,ABB, Chint, etc.
Battery switch, battery charger, emergency stop botton, 
indicator, meters, CT and all wiring and harness.
Batteries and cables
Speed & lub oil & water temp sensors,
A package of standard parts for assembly
3days
7 Exhaust System Industrial and residential silencer
Flexible connects and elbow
3days
8
Others
 
Special demands  
15kw Open Type Diesel Power Generator in 60Hz[Mbps02]
-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

15kw Open Type Diesel Power Generator in 60Hz[Mbps02]

Introduction of Maintenance grade(Interval) for the generator set
 

A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Send your message to this supplier

*From:
*To:
avatar Mrs. Jj, Mecca Power
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now