1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction

Product Details
Customization: Available
After-sales Service: Responsible
Warranty: 12 Months
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (21)
  • 1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
  • 1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
  • 1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
  • 1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
  • 1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
  • 1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Workshop
  • FAQ
Overview

Basic Info.

Model NO.
MC
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Engine Brand
Perkins
Alternator Brand
Stam Ford/Marathon/Mecca & Unique Brand for Usage
Control Panel
Deepsea/Comap/Deif/Smartgen and Others
Color
Optional
Canopy Type
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
Frequency(Hz)
50Hz/60Hz
Voltage Output
230/400V, Others as Application Requested
Application
Factory/Hospital/Construction/Airport
Accessory
Spare Parts Document
Governing Type
Mech/Elec/ECU/Ecm/Hpcr/Adec
Service Coverage
Global Service
ATS
as Application Requested
Certificate Available
CE, ISO, OEM Authorization etc.
Containerized Generator
Perkins Generator
Industrial Generator
Diesel Genset
Transport Package
Both Standard Marine Packing or Compact Packing.
Specification
As below Spec. with details
Trademark
Mecca
Origin
China
HS Code
85021
Production Capacity
1000/Year

Packaging & Delivery

Package Size
509.00cm * 223.00cm * 253.00cm
Package Gross Weight
9880.000kg

Product Description

Mecca Power, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled.

As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, Deutz, Man, Doosan, Stamford, Leroy Somer, Mecc Alte, Deepsea, ComAp, etc. Strongly focused on innovation and technical service, Mecca Power has been successfully used in hundreds of projects, widely applied in buildings,power plant, constructions, Telecom, data centers, mining, etc., covering over 90 countries in Asia, Africa, Oceania, Europe, Middle East and America.

1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
Product Description
 

MECCA 10-2500KVA PERKINS Diesel Generator is a high-performance, reliable power solution designed to meet the demanding energy needs of various industries and applications. Powered by PERKINS engines, renowned for their durability, efficiency, and low maintenance, this generator series ensures uninterrupted power supply in both prime and standby operations.

Key Features:

  1. Power Range: Available in a wide range from 10KVA to 2500KVA, catering to small-scale operations to large industrial requirements.

  2. PERKINS Engine: Equipped with PERKINS diesel engines, known for their robust construction, fuel efficiency, and long service life, ensuring reliable performance even in the toughest conditions.

  3. High Efficiency: Advanced engineering and design optimize fuel consumption, reducing operational costs while maintaining high power output.

  4. Durability: Built with high-quality materials and components, the generator is designed to withstand harsh environments and provide consistent performance over extended periods.

  5. Low Maintenance: PERKINS engines are engineered for minimal maintenance, reducing downtime and operational interruptions.

  6. Versatility: Suitable for a variety of applications, including construction sites, data centers, hospitals, commercial buildings, and industrial facilities.

  7. Advanced Control Systems: Features user-friendly control panels with advanced monitoring and protection systems, ensuring safe and efficient operation.

  8. Compliance: Meets international standards for emissions and noise levels, making it an environmentally friendly choice.

  9. Customizable Options: Available in open or enclosed configurations, with options for soundproofing, weatherproofing, and mobility to suit specific needs.

  10. Global Support: Backed by a worldwide network of service and support, ensuring prompt assistance and availability of spare parts.

1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/ConstructionVIEW MORE PRODUCTS CLIK HERE...
Specification
Powered by  Perkins                                                                                                                                                50HZ    220-440 V 10-2500KVA 
Model LTP PRP Engine Fuel Cons.L/H Cylinder Displacement Gov. Dimention L*W*H (MM) Weight (KGS)
KVA / KW  KVA/KW  Model Origin 100% L Open Open
MC10P 10 9 7 403A-11G1 CN/UK 2.6 3L 1.1 M 1370*750*1050 450 
MC10P 10 9 7 403D-11G CN 2.6 3L 1.1 M 1380*650*1250 450 
MC14P 14 11  13 10 403A-15G1 CN 3.7 3L 1.5 M 1480*650*1250 550 
MC14P 14 11  13 10 403D-15G CN 3.7 3L 1.5 M 1480*650*1250 550 
MC16P 16 13  15 12 403A-15G2 CN 4.32 3L 1.5 M 1480*650*1250 610 
MC23P 23 18  20 16 404A-22G1 CN 5.3 4L 2.2 M 1540*650*1250 650 
MC23P 23 18  20 16 404D-22G CN 5.3 4L 2.2 M 1540*650*1250 650 
MC30P 30 24 28 22 404D-22TG CN 7.1 4L 2.2 E 1540*650*1250 660 
MC33P 33 26  30 24 1103A-33G UK/IN 7.2 3L 3.3 M 1700*730*1280 830 
MC50P 50 40  45 36 1103A-33TG1 UK/IN 7.2 3L 3.3 M 1770*730*1280 910 
MC66P 66 53  60 48 1103A-33TG2 UK/IN 14.6 3L 3.3 M 1840*730*1280 960 
MC72P 72 57  65 52 1104A-44TG1 CN 14.8 4L 4.4 M 2020*760*1280 1080 
MC88P 88 70  80 64 1104C-44TAG1 CN 18.6 4L 4.4 E 2050*750*1270 1050 
MC88P 88 70  80 64 1104A-44TG2 CN 18.7 4L 4.4 M 2020*730*1280 1170 
MC113P 113 90  100 80 1104C-44TAG2 CN 26.9 4L 4.4 E 2090*800*1280 1130 
MC150P 150 120  135 108 1106A-70TG1 CN 29.9 6L 7 M 2230*950*1510 1520 
MC165P 165 132  150 120 1106A-70TAG2 CN 33.4 6L 7 M 2240*1020*1570 1580 
MC200P 200 160  180 144 1106A-70TAG3 CN 41.6 6L 7 M 2300*1020*1570 1700 
MC220P 220 176  200 160 1106A-70TAG4 CN 45.8 6L 7 E 2350*1020*1580 1750 
MC220P 220 176  200 160 1206A-E70TTAG1 UK 45.8 6L 7 ECM 2380*970*1800 1890 
MC250P 250 200  225 180 1506A-E88TAG2 USA 48.6 6L 8.8 ECM 2550*950*1600 2430 
MC250P 250 200  225 180 1206A-E70TTAG2 UK 51 6L 7 ECM 2400*970*1800 2000 
MC275P 275 220  250 200 1206A-E70TTAG3 UK 56.9 6L 7 ECM 2350*1050*1620 2230 
MC339P 339 271  306 245 1706A-E93TAG1 USA 62.5 6L 9.3 ECM 2830*1100*1650 3520 
MC383P 383 306  348 278 1706A-E93TAG2 USA 70.4 6L 9.3 ECM 2830*1100*1650 3600 
MC275P 275 220  250 200 1506A-E88TAG3 USA 55.5 6L 8.8 ECM 2750*1050*1760 2540 
MC330P 330 264  300 240 1506A-E88TAG5 USA 64.9 6L 8.8 ECM 2980*1090*1780 2870 
MC400P 400 320  350 280 2206C-E13TAG2 USA 75 6L 12.5 ECM 3150*1140*2050 3320 
MC450P 450 360  400 320 2206C-E13TAG3 USA 85 6L 12.5 ECM 3240*1140*2050 3460 
MC500P 500 400  450 360 2506C-E15TAG1 USA 99 6L 15 ECM 3430*1145*2120 3680 
MC550P 550 440  500 400 2506C-E15TAG2 USA 106 6L 15 ECM 3350*1160*2030 3600 
MC660P 660 528  600 480 2806C-E18TAG1A USA 123 6L 18.1 ECM 3230*1550*2050 4250 
MC715P 715 572  650 520 2806A-E18TAG2 USA 132 6L 18.1 ECM 3340*1550*2050 4350 
MC825P 825 660  750 600 4006-23TAG2A UK/IN 155 6L 22.9 E 4475*1700*2520 6080 
MC880P 880 704  800 640 4006-23TAG3A UK/IN 172 6L 22.9 E 4475*1720*2520 6110 
MC1000P 1000 800  900 720 4008TAG1A UK/IN 195 8L 30.5 E 4925*2140*2520 8200 
MC1100P 1100 880  1000 800 4008TAG2A UK/IN 215 8L 30.5 E 5025*2046*2555 8270 
MC1100P 1100 880  1000 800 4008TAG2 UK/IN 224 8L 30.5 E 5025*2046*2555 8270 
MC1250P 1250 1000  1125 900 4008-30TAG3 UK/IN 244 8L 30.5 E 5145*2285*2530 8900 
MC1375P 1375 1100  1250 1000 4012-46TWG2A UK/IN 259 12L 45.8 E 5000*2020*2400 9120 
MC1500P 1500 1200  1350 1080 4012-46TWG3A UK/IN 283 12L 45.8 E 4850*2020*2500 9120 
MC1650P 1650 1320  1500 1200 4012-46TAG2A UK/IN 310 12L 45.8 E 4850*2020*2500 9320 
MC1875P 1875 1500  1688 1350 4012-46TAG3A UK/IN 370 12L 45.8 E 5090*2230*2530 9880 
MC2000P 2000 1600  1850 1480 4016TAG1A UK/IN 383 16L 61.1 E 6240*2164*2670 10200 
MC2250P 2250 1800  2000 1600 4016TAG2A UK/IN 434 16L 61.1 E 6240*2164*2670 10600 
MC2500P 2500 2000  2250 1800 4016-61TRG3 UK/IN 470 16L 61.1 E 6250*2200*2694 11550 
Powered by  Perkins                                                                                                                                                                  60HZ   110-480 V  12-1880KVA 
Model LTP PRP Engine Fuel Cons.L/H Cylinder Displacement Gov. Dimention L*W*H (MM) Weight (KGS)
KVA / KW  KVA/KW  Model Origin 100% L Open Open
MC12P 12 10  11 8.8 403D-11G CN/UK 3 3L 1.1 M 1370*750*1050 450 
MC18P 18  13  16 12 403D-15G CN 4.2 3L 1.5 M 1480*650*1250 610 
MC20P 20  15  18 14 403A-15G2 CN 4.3 3L 1.5 M 1480*650*1250 610 
MC26P 26  21  24 19 404D-22G CN 6.2 4L 2.2 M 1540*650*1250 650 
MC36P 36  29  33 26 404D-22TG CN 8.3 4L 2.2 E 1540*650*1250 660 
MC39P 39  31  35 28 1103A-33G UK/IN 8.6 3L 3.3 M 1700*730*1280 830 
MC59P 59  47  54 43 1103A-33TG1 UK/IN 12.9 3L 3.3 M 1770*730*1280 910 
MC75P 75  59  68 54 1103A-33TG2 UK/IN 16.6 3L 3.3 M 1840*730*1280 960 
MC84P 84  66  76 60 1104A-44TG1 CN 17.8 4L 4.4 M 2020*760*1280 1170 
MC100P 100  79  91 72 1104A-44TG2 CN 22.3 4L 4.4 M 2020*730*1280 1170 
MC125P 125  100  112 90 1104C-44TAG2 CN 26.9 4L 4.4 E 2090*800*1280 1130 
MC169P 169  135  152 122 1106A-70TG1 CN 35.2 6L 7 M 2230*950*1510 1520 
MC186P 186  149  169 135 1106A-70TAG2 CN 38.2 6L 7 M 2240*1020*1570 1580 
MC220P 220  176  200 160 1106A-70TAG3 CN 46.4 6L 7 M 2300*1020*1570 1700 
MC248P 248  198  225 180 1206A-E70TTAG1 UK 54.5 6L 7 ECM 2340*970*1800 1860 
MC248P 248  198  225 180 1206A-E70TTAG2 UK 54.5 6L 7 ECM 2400*970*1800 2000 
MC248P 248  198  225 180 1206A-E70TTAG3 UK 54.5 6L 7 ECM 3570*1280*1850 2230 
MC320P 320 256  290 232 1506A-E88TAG3 USA 53.1 6L 8.8 ECM 2550*950*1600 2430 
MC389P 389 312  352 282 1506A-E88TAG5 USA 77.1 6L 8.8 ECM 2650*1120*1600 2650 
MC392P 392  314  356 285 1706A-E93TAG1 USA 75.2 6L 9.3 ECM 2710*1100*1650 3320 
MC392P 392  314  356 285 1706A-E93TAG2 USA 75.2 6L 9.3 ECM 2710*1100*1650 3400 
MC440P 440  352  400 320 2206C-E13TAG2 USA 92 6L 12.5 ECM 3150*1140*2050 3320 
MC440P 440  352  400 320 2206C-E13TAG3 USA 92 6L 12.5 ECM 3150*1140*2050 3320 
MC550P 550  440  500 400 2506C-E15TAG1 USA 100 6L 15 ECM 3400*1145*2120 3650 
MC550P 550  440  500 400 2506C-E15TAG2 USA 100 6L 15 ECM 3400*1145*2120 3650 
MC688P 688  550  625 500 2806C-E18TAG1A USA 130 6L 18.1 ECM 3460*1550*2220 4570 
MC688P 688  550  625 500 2806A-E18TAG2 USA 130 6L 18.1 ECM 3460*1550*2220 4570 
MC825P 825  660  750 600 4006-23TAG2A UK/IN 163 6L 22.6 E 4400*1700*2520 5900 
MC935P 935  748  850 680 4006-23TAG3A UK/IN 175 6L 22.6 E 4475*1720*2520 5940 
MC1100P 1100  880  1000 800 4008-TAG2 UK/IN 224 8L 30.5 E 4905*2046*2555 8200 
MC1375P 1375  1100  1250 1000 4012-46TWG2A UK/IN 266 12V 45.8 E 5025*2200*2530 8320 
MC1500P 1500 1200  1350 1080 4012-46TWG3A UK/IN 291 12V 45.8 E 5200*2200*2530 7850 
MC1650P 1650  1320  1500 1200 4012-46TAG2A UK/IN 315 12V 45.8 E 5285*2330*2530 9320 
MC1857P 1857  1485  1688 1350 4012-46TAG3A UK/IN 356 12V 45.8 E 5285*2230*2530 9430 
MORE INFO CONTACT US...
Workshop

1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction

1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction

1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction1350kVA 1500kVA 1875kVA UK Perkins Engine Backup Power Diesel Generator for Data Center/Construction
FAQ

Payment Terms:

By telegraphic transfer: 30% deposit on signing of sales contract; and balance 70% before dispatch. 
                                
Delivery:
Approximately 2-4 weeks upon order confirmation.

Service Guarantee:
Before Service: According to the clients' requirement and actual situation, we will furnish the technology consultation and kinds of information.  

After Service: Guarantee for one year or 1200 running hours (accord to whichever reach first) from installed date.
During the guarantee period, we will provide the free easy-damaged spare-parts for problems caused by our quality of production or raw material, except the damageable spare parts of diesel engine caused by customer's incorrect man-made operation. After checking, our company provides cost spare-parts maintenance for gensets .  


Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.

CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling. 
All items from following are seperately packed without connection.
 
SKD:Semi Knock Down Generator
Partially assembled generator. 
Part of the following items you choose will be assembled.
 
Advantage:
Prompt delivery
Reduced tax to win more competition
Lower transportation fees to save cost
Localized production to win more tenders. 
Increased production to offer more job opportunity for the government

Item
 

Service
 

Option
 

Delivery Time
 
1 Engine Doosan, Mtu, Mitsubishi, SME,  Volvo, 
Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, ect.
Marine and industry use 
Diesel, gas
2-45days
2 Alternator Stamford, Leroysomer,  Meccalte,  Marathon  and 
customer requested alternators
Medium and high voltage, 
Marine and industry use 
High IP Grade
CT Drop kits, PMG, AVR
2-15 days
3 Radiator Fast, Beworld brand
Original Radiator come with engine
Local made radiator with authorization by engine supplier
2-7days
4 Canopies Powder coated and form mounted canopy,completely break down with hings,
locks, raincap,bolts,screws, etc.
Exhaust pipe and flanges 
Standard silent type canopy package 
Denyo type canopy package 
Rental type canopy package 
Telecom type canopy package 
Super silent type canopy package 
Containerized type canopy package 
Customerized type canopy package
10days
5 Base frame Standard base or simple iron base
Anti-Vibration mountings
With/without tank, base tank volume no limited
Fuel gauges and high pressure fuel pipes
3days
6 Control system Controller: ComAp, DeepSea, Datacom, SmartGen etc.
Breaker:Delixi,ABB, Chint, etc.
Battery switch, battery charger, emergency stop botton, 
indicator, meters, CT and all wiring and harness.
Batteries and cables
Speed & lub oil & water temp sensors,
A package of standard parts for assembly
3days
7 Exhaust System Industrial and residential silencer
Flexible connects and elbow
3days
8
Others
 
Special demands  

-----------------------------------------------------------------------------------------------MAITAINENCE-------------------------------------------------------------------------------------------

General Troubleshooting            

This section lists the generating set for some common fault, the reasons for the failure and determines the            
method of fault. General operators can determine their own fault and note, maintenance it according to the            
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.            
Please remember the following suggestions before repairing:            
- Make sure that study the failure carefully before any operation.            
- Repair with the easiest way and most commonly used method.            
- Find the exact causes of failure and completely solve the fault.      
     

1. Generator Sets            
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.            
(Some models of control panel installed only parts of the following warning indicator light)
Icon Indicator Light Reason Fault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.


Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier